HP StorageWorks 8/80 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 348
FW-1430, Message, Probable Cause, switchStatusPolicySet, Recommended, Action, Severity
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 348 highlights
35 FW-1430 FW-1430 Message , [FW-1430], ,, WARNING, , Switch status change contributing factor . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty temperature sensors is greater than or equal to the policy set by the switchStatusPolicySet command. A temperature sensor is faulty when the sensor value is not in the acceptable range or is faulty. Recommended Replace the field-replaceable unit (FRU) with the faulty temperature sensor. Action Severity WARNING FW-1431 Message , [FW-1431], ,, WARNING, , Switch status change contributing factor Fan: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty fans is greater than or equal to the policy set by the switchStatusPolicySet command. A fan is faulty when sensor value is not in the acceptable range or is faulty. Recommended Replace the faulty or deteriorating fan field-replaceable units (FRUs). Action Severity WARNING FW-1432 Message , [FW-1432], ,, WARNING, , Switch status change contributing factor WWN: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty world wide name (WWN) cards is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty WWN card. Action Severity WARNING FW-1433 Message , [FW-1433], ,, WARNING, , Switch status change contributing factor CP: CP non-redundant. 290 Fabric OS Message Reference 53-1001157-01