HP StorageWorks 8/80 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 355
HAM System Messages, HAM-1001
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 355 highlights
Chapter HAM System Messages 36 HAM-1001 Message , [HAM-1001], , FFDC, CRITICAL, , Standby CP is not healthy, device status BAD, Severity = Probable Cause Indicates that a standby control processor (CP) device error is reported by the high-availability manager (HAM) Health Monitor, with a specific device and Log="YES" Class="NONE" Severity level. The severity level can be "critical", "major", or "minor". The active CP will continue to function normally, but because the standby CP is not healthy, non-disruptive failover is not possible. Recommended Action Reboot the standby CP blade by ejecting the card and reseating it. If the problem persists, replace the standby CP. Severity CRITICAL HAM-1002 Message , [HAM-1002], ,, INFO, , Standby CP is healthy. Probable Cause Indicates that all of the standby control processor (CP) devices monitored by the high-availability manager (HAM) Health Monitor report no error. Recommended No action is required. Action Severity INFO HAM-1004 Message Probable Cause , [HAM-1004], ,, INFO, , Processor rebooted - . Indicates the system has been rebooted either because of a user action or an error. The switch reboot can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands. Some examples of errors that might initiate this message are hardware errors, software errors, compact flash errors, or memory errors. The reboot reasons can be any of the following: • Hafailover • Unknown Fabric OS Message Reference 297 53-1001157-01