HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 339
Managing the Disk Array, on HP-UX, Option, Description
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 339 highlights
Option -C -c -Q -q Description Change the state of the specified disk array controller (A or B) to FAIL. The controller is failed by holding it in a reset state. NOTE! Before failing a controller, you must transfer ownership of all LUNs to the other controller. This command will fail if the controller you attempting to fail still owns any LUNs. See "Changing LUN Ownership" on page 316. Change the state of the specified disk array controller (A or B) to UNFAIL. This releases the controller form the reset state imposed by the fail command. If the controller cannot be returned to its operational state, it will remain in the FAIL state. Quiesce the specified disk array controller (A or B). This option causes the controller to stop responding to host I/Os. Unquiesce the specified disk array controller (A or B). This option resumes I/O activity on the specified controller. Managing the Disk Array on HP-UX 339