HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 383
Illegal Request- Controller Unable to Perform Reconfiguration
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 383 highlights
Additional Sense Code Additional Sense Code Qualifier Interpretation 85 01 Drive IO Request Aborted 87 00 IO Issued to Failed or Missing drive due to recently failed removed drive. This error can occur as a result of I/Os in progress at the time of a failed or removed drive. Microcode Download Error 87 08 87 0C 87 0E 88 0A 8A 00 The controller detected an error while downloading microcode and storing it in non-volatile memory. Incompatible Board Type For The Code Downloaded Download failed due to UTM LUN number conflict Controller Configuration Definition Inconsistent with Alternate Controller Subsystem Monitor NVSRAM values configured incorrectly. Illegal Command for Drive Access 8A 01 The initiator attempted to pass a command through to a drive that is not allowed. The command could have been sent in pass-thru mode or by attempting to download drive microcode. Illegal Command for the Current RAID Level 8A 10 The controller received a command that cannot be executed on the logical unit due to its RAID level configuration. Examples are parity verify or repair operations on a RAID 0 logical unit. Illegal Request- Controller Unable to Perform Reconfiguration as Requested The user requested a legal reconfiguration but the controller is unable to execute the request due to resource limitations. Managing the Disk Array on HP-UX 383