Wrong Disk Removed / Replaced
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 409 highlights
0x2247 0x2248 0x2249 0x224A 0x224B 0x224C Unrecovered Interrupted Write: Logged when a LUN is marked DEAD due to a media error failure during SOD. An error occurred during Interrupted Write processing causing the LUN to transition to the DEAD State. SK/ASC/ASCQ = 0x06/0x3F/0xEB will be offloaded for this error. Critical (0x1) Unrecovered Write Failure: Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0x80 indicating the controller set the drive state to "Failed - Write Failure". Critical (0x1) Disk Too Small: Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0x8B indicating the controller set the drive state to "Drive Capacity < Minimum". Critical (0x1) Wrong Sector Size: Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0x8C indicating the controller set the drive state to "Drive has wrong blocksize". Critical (0x1) Disk Format Failed: Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0x86 indicating the controller set the drive state to "Failed - Format failure". Critical (0x1) Wrong Disk Removed / Replaced: Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0x89 indicating the controller set the drive state to "Wrong drive removed/replaced". Informational (0x0) Notification (0x4) Failure (0x2) Notification (0x4) Notification (0x4) Notification (0x4) Notification (0x4) Volume (0xD) Drive (0x1) Drive (0x1) Drive (0x1) Drive (0x1) Drive (0x1) Managing the Disk Array on HP-UX 409