HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 405
Mark Disk for Replace and Rebuild
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 405 highlights
0x2229 0x222A 0x222B 0x222C 0x222D 0x222E 0x222F Failed Disk Internally: Logged when the configuration manager internally fails the device. Informational (0x0) Unassigned Disk Specified as Informational GHS: Logged when an unassigned (0x0) drive is specified as a global hot spare Disk Cold Replaced: Logged when the configuration manager finds a drive that has been cold replaced. i.e. Replace when the controller & subsystem were powered off. Informational (0x0) Disk Unassigned: Logged when a drive is to be marked unassigned, also Logged if an unknown drive that was part of a LUN is to be brought online Informational (0x0) Fail Disk Function Called: Logged when external interface or cfgDriveFailed is called. Informational (0x0) Mark Disk Removed: Logged when Informational a drive has is to be marked removed. (0x0) Mark Disk for Replace and Rebuild: Logged when a notification is received that a failed drive is to be replaced and that data reconstruction on this device should begin. Informational (0x0) Notification (0x4) Notification (0x4) Notification (0x4) Notification (0x4) Notification (0x4) Notification (0x4) Notification (0x4) Drive (0x1) Drive (0x1) Unknown (0x0) Drive (0x1) Drive (0x1) Drive (0x1) Drive (0x1) Managing the Disk Array on HP-UX 405