HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 598
Problem, Description, HW Event, Category, LED State, Status, Probable Cause/Solution
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 598 highlights
Problem Description The disk enclosure does not power on HW Event Category none System fault LED none is on Critical Buzzer sounds when BCC installed Critical BCC Fault LED is Critical on Fan LED is amber Critical LED State Status System none Power LED off Power Power Supply LED supply Not off Available Part Fault LED on BCC Fault flashing Critical Critical BCC Fault on Amber Critical Critical Probable Cause/Solution - Neither power cord is plugged in. - The power switch is not pressed. - AC breaker is tripped. - AC power source has failed. - The PDU/PDRU is defective. - Power switch is defective. - A faulty component is causing power supplies to turn off. Remove all components and reinsert one at a time until the faulty component is isolated. - The power supply is not plugged in. - The PDU/PDRU or primary power source has failed. A component has failed. See problem descriptions below. BCC DIP switch settings do not match peer BCC switch settings. Reset switches. BCC hardware is faulty. Replace the BCC. Fan has slowed or stopped. Replace the fan. 598