HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 392
Third Party Logout Reset
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 392 highlights
Event Number 0x1201 0x1202 0x1203 0x1204 0x1205 0x1206 0x1207 Event Description Priority LIP Reset Received: Logged when a Informational selective LIP reset is received. (0x0) Target Reset Received: Logged when a Target Reset if received. Informational (0x0) Third Party Logout Reset Received: Logged when a Third Party Logout with the Global Logout bit set. This is treated as a Target Reset by the controller. Informational (0x0) Internal Structure Initialization Error: Logged when a controller is unable to initialize an internal structure. Informational (0x0) Internal General Error: Logged when an internal error (e.g. unable to obtain memory, unable to send frame) occurs. Informational (0x0) Link Error Threshold: Logged when Link Error count exceeds the threshold value after the initial notification. Informational (0x0) Link Error Threshold Critical: Logged when Link Error count exceeds the threshold the first time. Critical (0x1) Category Error (0x1) Error (0x1) Error (0x1) Error (0x1) Error (0x1) Error (0x1) Error (0x1) Component Controller (0x8) Controller (0x8) Controller (0x8) Controller (0x8) Controller (0x8) Controller (0x8) Controller (0x8) 392