HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 481
Treat BusDeviceReset as BUS RESET is
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 481 highlights
0x1b 0x00 Drive-side Queuing Options Drv sorting OFF. = optimized. Dynamic queue depth 0x1c 0x04 Error reporting Option (Byte 0x1C) . . . drvs/dead LUNS at start of day Report failed 0x1d 0x80 Error reporting Option (Byte 0x1D) . . . as Chk Conditions Rprt VU Unit Attn 0x1e 0x00 UPS options No feature support 0x1f 0x00 AC Polling option NOT POLL Does 0x20 0x00 UPS warning time options 0x00 0x.00 0x22 0x00 Low UPS BATTERY recharge time . . .0 minutes 0x24 0x00 Inquiry Non-owned LUN device type. . .0x.02x 0x25 0x00 Parity scan options enabled. Auto parity scan NOT 0x26 0x00 LUN takeover UnitAtn ASC 0x00 0x27 0x00 Serial Status Display 0x00 0x28 0x04 Misc. options byte 0x28 Synchronize NVSRAM is SET Load Network Software is NOT SET Report in Inquiry as SCSI-3 is NOT SET Treat BusDeviceReset as BUS RESET is NOT SET Disable use of FUA is NOT SET Disable creation of default LUN NOT SET 0x29 0x2c Misc. options byte 0x29 Don't fail sub-encls drives on sub-enclsr failureSET 0x2a 0x64 Drive cmd timeout value 10 seconds 0x2b 0x8a Caching Options Enable Write-Back cache SET Enable cache WITHOUT batteries NOT SET HP-UX Diagnostic Tools 481