HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 381
Managing the Disk Array
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 381 highlights
Additional Sense Code Additional Sense Code Qualifier Interpretation 44 00 Internal Target Failure The controller has detected a hardware or software condition that does not allow the requested command to be completed. If the accompanying sense key is 0x04: Indicates a hardware failure. The controller has detected what it believes is a fatal hardware or software failure and it is unlikely that a retry would be successful. 45 00 If the accompanying sense key is 0x0B: Indicates an aborted command. The controller has detected what it believes is a temporary software failure that is likely to be recovered if retried. Selection Time-out on a Destination Bus 47 00 A drive did not respond to selection within a selection time-out period. SCSI Parity Error 48 00 The controller detected a parity error on the host SCSI bus or one of the drive SCSI buses. Initiator Detected Error Message Received 49 00 The controller received an Initiator Detected Error Message from the host during the operation. Invalid Message Error The controller received a message from the host that is not supported or was out of context when received. Managing the Disk Array on HP-UX 381