UPS Battery Supplying Power
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 414 highlights
0x2703 Recovered Processor DRAM Error: Logged when the controller has encountered recoverable processor DRAM ECC errors (below the maximum threshold) Informational (0x0) Notification (0x4) Controller (0x8) Event Number 0x2800 0x2801 0x2802 0x2803 0x2805 Event Description Priority Power Supply State Changed: Logged when a power supply changes state Informational (0x0) UPS Battery Supplying Power to Subsystem: The UPS battery is now supplying power to the subsystem. Informational (0x0) UPS Battery Good: The UPS battery has charged and transitioned to the good state Informational (0x0) UPS Battery 2 Minute Warning: The UPS battery has transitioned given the 2 minute warning. The UPS has signaled that it has 2 minutes of power left before failing. The controllers will flush any dirty data in their caches and turn off data caching. Informational (0x0) Line State Change: Logged when a discreet line state change is detected and an AEN is posted. This can either be a good to bad transition or bad to good. This does not include the cache battery line. Cache battery events are logged by the cache manager Informational (0x0) Category Notification (0x4) Notification (0x4) Notification (0x4) Notification (0x4) Notification (0x4) Component Power Supply (0x2) Battery (0x9) Battery (0x9) Battery (0x9) Unknown (0x0) 414