HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 550
Symptom, Possible Cause, Procedure
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 550 highlights
Symptom Controller LED (front cover) is ON and the fan LED is off. Software issued a Controller error message Controller enclosure and Fan LED (front cover) are on Possible Cause Procedure A Controller missing or unplugged B Controller failed C One or more memory modules failed D Controller enclosure midplane failed Check the Power LEDs on both controller modules. If one Power LED is off, make sure that the module is plugged in correctly and its handles are locked in place. If the Fault LED remains ON after replacing the Controller, go to cause C. Replace the memory modules. If the Fault LED remains ON after replacing the memory, go to cause D. Replace the Midplane. If the Fault LED remains ON after replacing the midplane, call the factory service center. A Controller failed - Check the Fan LED on the front cover. If it is on, go to "Troubleshooting Controller Fan Module Problems" on page 561. If not, continue at the next step. - Replace the failed Controller. A Controller enclosure fan - Stop all activity to the Controller module failure caused one or and turn OFF the power. both Controller(s) to - Replace the failed Controller enclosure overheat fan module. - Allow the Controller to cool down, then turn ON the power. - Check both Controllers for fault LEDs. If a Controller Fault LED turns on, replace the failed Controller. 550