HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 410
Disk Failed Rebuild at Start of Day
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 410 highlights
0x224D 0x224E 0x224F 0x2250 0x2251 0x2252 No Response From Disk: Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0x85 indicating the controller set the drive state to "Failed - No Response". Replaced Disk Failed: Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0x82 indicating the controller set the drive state to "Failed" be it was unable to make the drive usable after replacement. Global Hot Spare Not Large Enough: Logged when a defined Global Hot Spare device is not large enough to cover all of the drives in the subsystem. LUN Failure: Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0xE0 indicating Logical Unit Failure. Disk Failed Rebuild at Start of Day (SOD): Logged when the configuration manager posts and UA/AEN of ASC/ASCQ = 0x3F/0x8E indicating that the drive failed due to a reconstruction failure at SOD. Device Failed During Interrupted Write: Logged when the specified device is failed during interrupted write processing. SK/ASC/ASCQ = 0x06/0x3F/0x98 will be offloaded for each failing device. Critical (0x1) Critical (0x1) Informational (0x0) Critical (0x1) Critical (0x1) Critical (0x1) Notification (0x4) Failure (0x2) Notification (0x4) Failure (0x2) State (0x5) Notification (0x4) Drive (0x1) Drive (0x1) Drive (0x1) Volume (0xD) Drive (0x1) Drive (0x1) 410