HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 599
Troubleshooting, Problem, Description, HW Event, Category, LED State, Status, Probable Cause/
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 599 highlights
Troubleshooting Problem Description Power Supply LED is amber Temperature is over limit Temperature is under limit Voltage is over limit Voltage is under limit HW Event Category Critical Critical Major Warning Critical Major Warning Critical Major Warning Critical Major Warning LED State Amber none none none none none none none none Status Probable Cause/Solution Critical Critical Temp is >54.5º C Non-critical Temp is >36º C - An incompatible or defective component caused a temporary fault. - Power supply hardware is faulty. Unplug the power cord and wait for the LED to turn off. Reinsert the power cord. If fault persists, replace the power supply. - A fan is faulty. Check status and correct. - Airflow is obstructed; vents are blocked. - One or more slots are empty. - Power supply is faulty. Check status and correct. - Room temperature is too high. If ambient temperature cannot be reduced in a reasonable time, turn OFF product to prevent shortened life. - Temperature sensor is faulty. Compare temperature reported by peer BCC. Critical Temp is