HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 364
Spare--drive Is Missing
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 364 highlights
Status Definition/Action AM60: READ FAILED STM: FLT - 19 AM60: WRONG BLOCK SIZE STM: OFF - 22 AM60: DISK LOCKED OUT STM: UNSUPP The disk array could not read from the disk. Replace the failed disk. The disk uses an incompatible block size (not 512 bytes). Replace with a supported disk. The disk is not supported. Install a supported disk. AM60: NON-SUPPORTED ID STM: FLT - 33 AM60: NO RESPONSE OR DEFINED GLOBAL HOT SPARE--DRIVE IS MISSING STM: FLT - 35 AM60: CAPACITY LESS THAN MINIMUM STM: OFF - 38 AM60: NON-SUPPORTED CHANNEL & ID STM: FLT - 49 AM60: FORMAT OR RECONSTRUCT FAILED STM: FLT - 51 The command made a request using an unsupported ID. Retry the command with the proper parameters. The disk is not responding. It may have failed or been removed. Replace or reinstall the disk. A disk was replaced by a disk with lower capacity. Install disk with the proper capacity. The disk is unsupported. Install a supported disk. The command made a request to an unsupported channel and ID. Retry the command using the proper channel & ID. The disk failed while being formatted or rebuilt. Replace the disk. AM60: WRITE FAILED STM: FLT - 67 The disk array could not write to the disk. Replace the failed disk. AM60: UNDEFINED STM: FLT - xxx AM60: FAILED VIA MODE SELECT STM: FLT - 83 The disk is an unknown state. The disk was failed using a host-initiated command. 364