HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 375
Controller Firmware Changed Through Auto Code Synchroni
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 375 highlights
Additional Sense Code Additional Sense Code Qualifier Interpretation 29 04 Device Internal Reset 29 81 The controller has reset itself due to an internal error condition. Default Configuration has been Created 29 82 The controller has completed the process of creating a default logical unit. There is now an accessible logical unit that did not exist previously. The host should execute its device scan to find the new logical unit. Controller Firmware Changed Through Auto Code Synchronization 2A 01 The controller firmware has been changed through the Auto Code Synchronization (ACS) process. Mode Parameters Changed 2A 02 The controller received a request from another initiator to change the mode parameters for the addressed logical unit. This error notifies the current initiator that the change occurred. This error may also be reported in the event that Mode Select parameters changed as a result of a cache synchronization error during the processing of the most recent Mode Select request. Log Parameters Changed The controller received a request from another initiator to change the log parameters for the addressed logical unit. This error notifies the current initiator that the change occurred. This error is returned when a Log Select command is issued to clear the AEN log entries. Managing the Disk Array on HP-UX 375