HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 413
Default LUN Created at SOD
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 413 highlights
Event Number 0x2600 0x2601 0x2602 0x2603 0x2604 0x2605 0x2700 0x2702 Event Description Priority ACS Download Start: Logged when Informational an ACS Download is started (0x0) ACS Download Completed: Logged after the controller has been rebooted after auto code synchronization has been preformed. An ASC/ASCQ value of 0x29/0x82 is also logged with this event Informational (0x0) ACS Failed: Logged when auto code Informational synchronization failed (0x0) Default LUN Created at SOD: Logged when the default LUN was created at SOD Informational (0x0) Persistent Memory Parity Error: Logged when SOD detects that the persistent memory parity error state has been set. Informational (0x0) Start of Day Complete: Logged when the controller has completed initialization. Informational (0x0) RPA Memory Parity Error: Logged during start of day if a parity error is found in RPA memory. Informational (0x0) RPA Unexpected Interrupt: Logged when an unexpected RPA Interrupt is detected Informational (0x0) Category Component Notification Controller (0x4) (0x8) Notification Controller (0x4) (0x8) Error (0x1) State (0x5) Controller (0x8) Volume (0xD) Error (0x1) Controller (0x8) Notification Controller (0x4) (0x8) Error (0x1) Controller (0x8) Notification Controller (0x4) (0x8) Managing the Disk Array on HP-UX 413