HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 377
Drive Marked Offline Due to Internal Recovery Procedure
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 377 highlights
Additional Sense Code Additional Sense Code Qualifier Interpretation 3F 8N Drive No Longer Usable. The controller has set a drive to a state that prohibits use of the drive. The value of N in the ASCQ indicates the reason why the drive cannot be used. 3F 98 0 - The controller set the drive state to "Failed - Write failure" 1 - Not used 2 - The controller set the drive state to "Failed" because it was unable to make the drive usable after replacement. A format or reconstruction error occurred. 3 - Not used 4 - Not used 5 - The controller set the drive state to "Failed - No response" 6 - The controller set the drive state to "Failed - Format failure" 7 - The controller set the drive state to "User failed via Mode Select" 8 - Not used 9 - The controller set the drive state to "Wrong drive removed/ replaced" A - Not used B - The controller set the drive state to "Drive capacity < minimum" C - The controller set the drive state to "Drive has wrong block size" D - The controller set the drive state to "Failed - Controller storage failure" E - Drive failed due to reconstruction failure at Start of Day (SOD) Drive Marked Offline Due to Internal Recovery Procedure An error has occurred during interrupted write processing causing the LUN to transition to the DEAD state. Drives in the drive group that did not experience the read error will transition to the Offline state (0x0B) and log this error. Managing the Disk Array on HP-UX 377