HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 398
Request to Update Cache Manager
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 398 highlights
Event Number 0x2101 0x2102 0x2106 0x2107 0x2109 0x210A Event Description Priority Alternate Controller Late Check In: Logged when the alternate controller check in late Informational (0x0) Controller Cache Mirroring Not Synchronized: The mirror is out of sync with the alternate controllers mirror. Informational (0x0) Request to Update Cache Manager DACSTORE: A request to update the cache managers DACSTORE area was received. Informational (0x0) Request to Clear Cache Manager DACSTORE: A request to clear the cache managers DACSTORE area was received. Informational (0x0) Controller Hardware Cache Size Mismatch: Write back cache could not be enabled to due different cache sizes of the controllers in the subsystem. ASC/ASCQ value of 0xA1/0x00 is also logged with this event. Informational (0x0) Caching Not Enabled or Internally Disabled: Write back cache could not be enabled or was internally disabled. The ASC/ASCQ value of 0xA0/0x00 is also logged with this event. Informational (0x0) Category Notification (0x4) Notification (0x4) Notification (0x4) Notification (0x4) Error (0x1) Notification (0x4) Component Controller (0x8) Controller (0x8) Controller (0x8) Controller (0x8) Controller (0x8) Controller (0x8) 398