IBM 326m Hardware Maintenance Manual - Page 101
diagnostics.
UPC - 000435835093
View all IBM 326m manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
Note: See "System" on page 100 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 175 (Hardware error) v System board 184 (Power-on password damaged) 1. Run the Configuration/Setup Utility program. 2. System board. 187 (VPD serial number not set.) 1. Set serial number in the Configuration/Setup Utility program. 2. System board. 188 (Bad EEPROM CRC #2) 1. Run the Configuration/Setup Utility program. 2. System board. 189 (An attempt was made to access the server with invalid passwords) v Run the Configuration/Setup Utility program, and enter the administrator password. 201 1. DIMM (Memory test error.) If the server does not have the latest level of BIOS installed, 2. System board update the BIOS to the latest level and run the diagnostic program again. 289 (DIMM disabled by POST or user) 1. Run the Configuration/Setup Utility program, if the DIMM was disabled by the user. 2. Disabled DIMM, if not disabled by user. 3. System board 301 (Keyboard or keyboard controller error) 1. Keyboard 2. System board 303 (Keyboard controller error) v System board 602 (Invalid diskette boot record) 1. Diskette 2. Diskette drive 3. Cable 4. System board 662 (Diskette drive configuration error) 1. Run the Configuration/Setup Utility program and diagnostics. 2. Diskette drive. 3. Drive cable. 4. System board. 962 (Parallel port error) 1. Disconnect the external cable on the parallel port. 2. Run the Configuration/Setup Utility program. 3. System board. 1162 (Serial port configuration conflicts) 1. Run the Configuration/Setup Utility program and ensure that the IRQ and I/O port assignments needed by the serial port are available. 2. If all interrupts are being used by adapters, remove an adapter or force other adapters to share an interrupt. Chapter 7. Symptom-to-FRU index 91