IBM 326m Hardware Maintenance Manual - Page 61
connecting
UPC - 000435835093
View all IBM 326m manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
5. Remove the fan from the server: a. Disconnect the fan cable from the system board. b. Lift the fan out of the server, noting its orientation in the server. Fan 5 Fan 4 Fan 3 Fan 2 Airflow Fan 1 6. Position the replacement fan correctly: a. The airflow arrow on the side of the fan must point toward the rear of the server. b. Fans 2, 4, and 5 are positioned so that the fan cable exits from the fan near the top of the server. c. Fan 3 is positioned so that the fan cable exits from the fan near the bottom of the server (a 180° difference from Fans 2, 4, and 5). Note: Correct airflow is from the front to the rear of the server. 7. Connect the replacement fan cable to the system board. Note: If you are replacing more than one fan, install all fans in the server before connecting the cables to the system board. Chapter 4. Installing options 51