JVC BR-DV6000U User Manual - Page 92

Ed: Memory Sw Preset B/j1, D3: Memory Sw Sense J1

Page 92 highlights

RS-232C INTERFACE - RS-232C commands - (continued) Table Command Description E7 TIMER MODE SELECT : For selecting the counter mode. Following this command, send 1-byte data corresponding to the counter mode. High Low Counter mode 1 TC 3 (Fixed) 2 CTL 5 UB 8E DATA SELECT : For setting the date. Following this command, send 6-byte numeric data. Specify month, date and year (in this sequence) with two digits for each. 8F TIME SELECT : For setting the time. Following this command, send 6-byte numeric data. Specify hour, minute and second (in this sequence) with two digits for each. Ⅵ Menu switch setup command ● ED: MEMORY SW PRESET (B/J1) This command is for changing the VCR's menu switches. Following this command, transmit the data (3 bytes) corresponding to the menu switch to be changed. Example: Set SYNC SELECT to EXTERNAL. In the diagram below, the data corresponding to the setting of EXTERNAL show that DATA 0, D2 No. 1 bit and D2 No. 0 bit are, respectively, 01, 0 and 1. Set the command by transmitting data in a way that the corresponding bit values match them. DATA0 D1 D2 TXD EDH 01H RXD 0AH 0AH 0AH 0AH Bit No. 7 6 5 4 3 2 1 0 D2 EXTERNAL : 0 1 ● D3: MEMORY SW SENSE (J1) This command is for checking the VCR's menu switch setting. Following this command, transmit the data (DATA0) corresponding to the menu switch to be checked. You can confirm the setting with the bit count of the returned data (D1, D2). Example: Check the SYNC SELECT setting. As in the diagram below, the setting can be checked by confirming the values for the menu switch. In this example, check the values for DATA0 (namely 01), D2 No. 1 and No. 0 of the returned data. DATA0 TXD D3H 01H RXD 0AH D1 D2 Bit No. 7 6 5 4 3 2 1 0 D2 AUTO : 1 1 EXTERNAL : 0 1 92

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

92
RXD
0AH
EDH
0AH
01H
0AH
D1
7654321
01
EXTERNAL :
0
D2
DATA0
0AH
D2
TXD
RXD
01H
D3H
0AH
D1
7654321
1 1
0 1
AUTO :
EXTERNAL :
0
D2
D2
TXD
DATA0
RS-232C INTERFACE
– RS-232C commands – (continued)
E7
8E
8F
TIMER MODE SELECT :
For selecting the counter mode. Fol-
lowing this command, send 1-byte
data
corresponding to the counter
mode.
DATA SELECT :
For setting the date. Following this
command, send 6-byte numeric data.
Specify month, date and year (in this
sequence) with two digits for each.
TIME SELECT :
For setting the time. Following this
command, send 6-byte numeric data.
Specify hour, minute and second (in
this sequence) with two digits for each.
1
2
5
TC
CTL
UB
Low
High
Counter mode
3
(Fixed)
²
Menu switch setup command
ED: MEMORY SW PRESET (B/J1)
This command is for changing the VCR’s menu
switches. Following this command, transmit the
data (3 bytes) corresponding to the menu switch
to be changed.
Example: Set SYNC SELECT to EXTERNAL.
In the diagram below, the data corresponding to
the setting of EXTERNAL show that DATA 0, D2
No. 1 bit and D2 No. 0 bit are, respectively, 01, 0
and 1.
Set the command by transmitting data in a
way that the corresponding bit values match them.
Bit No.
D3: MEMORY SW SENSE (J1)
This command is for checking the VCR’s menu
switch setting. Following this command, transmit
the data (DATA0) corresponding to the menu switch
to be checked.
You can confirm the setting with the bit count of
the returned data (D1, D2).
Example: Check the SYNC SELECT setting.
As in the diagram below, the setting can be checked
by confirming the values for the menu switch. In
this example, check the values for DATA0 (namely
01), D2 No. 1 and No. 0 of the returned data.
Bit No.
Table
Command
Description