Lexmark MX722 Forms and Bar Code Card P4.2 Technical Reference - Page 14
Command, Function parameters, PCL 5 emulation: HP
View all Lexmark MX722 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
PCL 5 emulation: HP Command Esc(s#H or AEC)s#H Esc(s#V or AEC)s#V Lexmark Confidential until announced 14 Function parameters Selects the HRT font. The numeric value of # is of the form ABC, where: • A is the font style. 0-Use the default value (bold). 1-Regular. 2-Italic. 3-Bold. 4-Bold Italic. • B is the font size. 0-Automatic font size (default). • C is the font typeface. 0-Courier (default). 1-Letter Gothic. 2-Univers. 3-Univers Condensed. 4-CG Times. 5-OCR‑B. For example: Esc(s304h24620T Selects EAN/JAN-8 with automatically sized CG Times Bold text. Because parameters v, p, b, and s are not specified, their values default to: • v-0.7 in. • p-Print the text half embedded. • b1, s1-0.013 in. • b2, s2-0.027 in. • b3, s3-0.04 in. • b4, s4-0.053 in. Selects the bar height in points (1/72 in.). The bar height can vary from a minimum of 3 points (0.04 in. or 1 mm) to a maximum of 960 points (13.33 in. or 33 cm). Symbologies where #v is a fixed value are excluded. For example: Esc(s36v24750T Selects the Codabar symbology with a bar height of 0.5 in. Because parameters p, b, s, and h are not specified, their values default to: • p-Do not print the text. • b1, s1-0.01 in. • b2, s2-0.03 in. • h-Not applicable because of #p parameter value.