Lexmark Confidential until announced PostScript emulation 70 Values for /Symbology key Command Function parameters (/Height, /Bars, and /Spaces units are in 1/600 in.) /Symbology Select the bar code Bar code symbology /Height Default parameters1 /EmbedTe /Bars and /Spaces xt [num num num num] Character s Sym bol2 Chec ksum encoded lengt char h acter /Codabar Codabar 240 1 6 18 N/A N/A Mixed N/A No /CodabarChk Codabar with 240 1 mod16 check digit 6 18 N/A N/A Mixed N/A Yes /Code128A Code 128 A 240 1 6 12 18 24 Mixed N/A Yes /Code128auto Code 128 240 1 autoswitch 6 12 18 24 Mixed N/A Yes /Code128B Code 128 B 240 1 6 12 18 24 Mixed N/A Yes /Code128C Code 128 C 240 1 6 12 18 24 Mixed N/A Yes /Code39 Code 3 of 9 240 1 6 18 N/A N/A Mixed N/A No /Code39Chk Code 3 of 9 240 1 with check digit 6 18 N/A N/A Mixed N/A Yes /Code39Ext Code 3 of 9 240 1 extended 6 18 N/A N/A Mixed N/A No /Code39ExtChk Code 3 of 9 240 1 extended with check digit 6 18 N/A N/A Mixed N/A Yes /Code93 Code 93 240 1 6 12 18 24 Mixed N/A Yes /Code93Ext Code 93 extended 240 1 6 12 18 24 Mixed N/A Yes /Danish39 Danish PTT 3 240 1 of 9 6 18 N/A N/A Mixed 10 Yes3 /French39 French Postal 300† 4† 3 of 9 A/R 6† 18† N/A N/A Mixed 10 Yes3 /EAN-8 EAN/JAN-8 420 3 8 16 24 32 Numeric 7 Yes3 1 For all bar code symbologies, the default value for /FontName key is Courier Bold. 2 Does not include the checksum character. 3 If the embedded text is specified, then the checksum character is always printed. 4 ISBN is 10 or 15 and ISSN is 10, 12, or 15 (plus optional hyphens). 5 Except for the possibility of an xas a checksum. † Fixed value.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

Values for /Symbology key
Command
Function parameters (/Height, /Bars, and /Spaces units are in 1/600 in.)
/Symbology
Select the bar
code
Default parameters
1
Character
s
encoded
Sym
bol
2
lengt
h
Chec
ksum
char
acter
Bar code
symbology
/Height
/EmbedTe
xt
/Bars and /Spaces
[num
num
num
num]
/Codabar
Codabar
240
1
6
18
N/A
N/A
Mixed
N/A
No
/CodabarChk
Codabar with
mod16 check
digit
240
1
6
18
N/A
N/A
Mixed
N/A
Yes
/Code128A
Code 128 A
240
1
6
12
18
24
Mixed
N/A
Yes
/Code128auto
Code 128
autoswitch
240
1
6
12
18
24
Mixed
N/A
Yes
/Code128B
Code 128 B
240
1
6
12
18
24
Mixed
N/A
Yes
/Code128C
Code 128 C
240
1
6
12
18
24
Mixed
N/A
Yes
/Code39
Code 3 of 9
240
1
6
18
N/A
N/A
Mixed
N/A
No
/Code39Chk
Code 3 of 9
with check
digit
240
1
6
18
N/A
N/A
Mixed
N/A
Yes
/Code39Ext
Code 3 of 9
extended
240
1
6
18
N/A
N/A
Mixed
N/A
No
/Code39ExtChk
Code 3 of 9
extended
with check
digit
240
1
6
18
N/A
N/A
Mixed
N/A
Yes
/Code93
Code 93
240
1
6
12
18
24
Mixed
N/A
Yes
/Code93Ext
Code 93
extended
240
1
6
12
18
24
Mixed
N/A
Yes
/Danish39
Danish PTT 3
of 9
240
1
6
18
N/A
N/A
Mixed
10
Yes
3
/French39
French Postal
3 of 9 A/R
300†
4†
6†
18†
N/A
N/A
Mixed
10
Yes
3
/EAN-8
EAN/JAN-8
420
3
8
16
24
32
Numeric
7
Yes
3
1
For all bar code symbologies, the default value for /FontName key is Courier Bold.
2
Does not include the checksum character.
3
If the embedded text is specified, then the checksum character is always printed.
4
ISBN is 10 or 15 and ISSN is 10, 12, or 15 (plus optional hyphens).
5
Except for the possibility of an
x
as a checksum.
† Fixed value.
Lexmark Confidential until announced
PostScript emulation
70