Lexmark MX722 Forms and Bar Code Card P4.2 Technical Reference - Page 56

PCL specifications for composite bar codes, 24811T specifies RSS-14 Truncated.

Page 56 highlights

Lexmark Confidential until announced PCL 5 emulation: Lexmark 56 PCL specifications for composite bar codes Field name Type Range Default value Description Symbology int N/A N/A Required. ID • 24600T specifies UPC-A. • 24601T specifies UPC-A+2. • 24602T specifies UPC-A+5. • 24610T specifies UPC-E. • 24611T specifies UPC-E+2. • 24612T specifies UPC-E+5. • 24620T specifies EAN-8. • 24621T specifies EAN-8+2. • 24622T specifies EAN-8+5. • 24630T specifies EAN-13. • 24631T specifies EAN-13+2. • 24632T specifies EAN-13+5. • 24710T specifies UCC-128. • 24810T specifies RSS-14 standard. • 24811T specifies RSS-14 Truncated. • 24812T specifies RSS-14 Stacked. • 24814T specifies RSS-14 Limited. • 24815T specifies RSS-14 Expanded. Module int height Depends on the Depends on the default Corresponds to the HP #v parameter. module height range of module height of the the linear component linear component Module int width Depends on the Depends on the default Corresponds to the HP #b parameter. module width range of module width of the the linear component linear component HRT location int 0-Use the default Depends on the default Corresponds to the HP #p parameter. value (half embedded). 1-No HRT. 2-Print the text embedded. 3-Print the text half HRT location of the linear component, except for UCC-128, which uses 4 as its default value Note: If an invalid value is specified, then the default value is used. embedded. 4-Print the text below embedded. The dimensions of the composite bar code may be varied in only two directions. • The module height of the linear component is varied using the v parameter. • The module width of the linear component is varied using the b parameter.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

PCL specifications for composite bar codes
Field name
Type
Range
Default value
Description
Symbology
ID
int
N/A
N/A
Required.
24600T specifies UPC-A.
24601T specifies UPC-A+2.
24602T specifies UPC-A+5.
24610T specifies UPC-E.
24611T specifies UPC-E+2.
24612T specifies UPC-E+5.
24620T specifies EAN-8.
24621T specifies EAN-8+2.
24622T specifies EAN-8+5.
24630T specifies EAN-13.
24631T specifies EAN-13+2.
24632T specifies EAN-13+5.
24710T specifies UCC-128.
24810T specifies RSS-14 standard.
24811T specifies RSS-14 Truncated.
24812T specifies RSS-14 Stacked.
24814T specifies RSS-14 Limited.
24815T specifies RSS-14 Expanded.
Module
height
int
Depends on the
module height range of
the linear component
Depends on the default
module height of the
linear component
Corresponds to the HP
#v
parameter.
Module
width
int
Depends on the
module width range of
the linear component
Depends on the default
module width of the
linear component
Corresponds to the HP
#b
parameter.
HRT location
int
0
—Use the default
value (half embedded).
1
—No HRT.
2
—Print the text
embedded.
3
—Print the text half
embedded.
4
—Print the text below
embedded.
Depends on the default
HRT location of the
linear component,
except for UCC-128,
which uses
4
as its
default value
Corresponds to the HP
#p
parameter.
Note:
If an invalid value is specified,
then the default value is used.
The dimensions of the composite bar code may be varied in only two directions.
The module height of the linear component is varied using the
v
parameter.
The module width of the linear component is varied using the
b
parameter.
Lexmark Confidential until announced
PCL 5 emulation: Lexmark
56