Lexmark MX722 Forms and Bar Code Card P4.2 Technical Reference - Page 67

Arguments for one-dimensional bar codes, Intelligent Mail bar code descriptors

Page 67 highlights

Lexmark Confidential until announced PostScript emulation 67 Key /Units Range N/A Default value N/A Description Optional. The value is 1/600 in. Intelligent Mail bar code descriptors Key /Symbology /Units Type name name /Bars /Pitch /TrackerHeight /QuietZone /AscenderHeight int int int [int int] int /EmbedText name Range Default value Description N/A /IntelligentMail Identifies the bar code symbology. /300ths /600ths /1200ths /600ths The value is fixed. 38-63 dec 50 dec Sets the bar width in /Units. 20-24 dec 23 dec Sets the number of bars that print per inch. 100-160 dec 127 dec Sets the tracker height in /Units. [0-10000][0-10000] [150 150] The value is fixed. 100-210 135 Sets the ascender and descender offset in 1/100 mm. The total height of an ascender or descender is the sum of this field and the tracker height. /NoText /Under /Above /NoText Optional. Determines the HRT location printed with the bar code. Arguments for one-dimensional bar codes Key Type Default value Description /Symbology name N/A Required. For a list of valid values, see "Values for / Symbology key" on page 70. /Units N/A 1/600 in. Optional. Other valid values are 1/300, 1/1200, and 1/720 in., which also apply to height and width units for any one-dimensional symbology. 1 For the French Postal symbology, /Special and /PrintCheckChar are always set to true and cannot be changed to false.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

Key
Range
Default value
Description
/Units
N/A
N/A
Optional.
The value is 1/600 in.
Intelligent Mail bar code descriptors
Key
Type
Range
Default value
Description
/Symbology
name
N/A
/IntelligentMail
Identifies the bar code
symbology.
/Units
name
/300ths
/600ths
/1200ths
/600ths
The value is fixed.
/Bars
int
38–63 dec
50 dec
Sets the bar width in /Units.
/Pitch
int
20–24 dec
23 dec
Sets the number of bars that
print per inch.
/TrackerHeight
int
100–160 dec
127 dec
Sets the tracker height
in /Units.
/QuietZone
[int int]
[0–10000][0–10000]
[150 150]
The value is fixed.
/AscenderHeight
int
100–210
135
Sets the ascender and
descender offset in
1/100 mm.
The total height of an
ascender or descender is the
sum of this field and the
tracker height.
/EmbedText
name
/NoText
/Under
/Above
/NoText
Optional.
Determines the HRT location
printed with the bar code.
Arguments for one-dimensional bar codes
Key
Type
Default value
Description
/Symbology
name
N/A
Required.
For a list of valid values, see
“Values for /
Symbology key” on page
70
.
/Units
N/A
1/600 in.
Optional.
Other valid values are 1/300, 1/1200, and
1/720 in., which also apply to height and
width units for any one-dimensional
symbology.
1
For the French Postal symbology, /Special and /PrintCheckChar are always set to true and cannot be changed to
false.
Lexmark Confidential until announced
PostScript emulation
67