Pioneer 607CMX Technical Manual - Page 26
Special Instruction Hanging on the wall - pdp speakers
UPC - 012562824413
View all Pioneer 607CMX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Special Instruction (Hanging on the wall) 3.4.2 Hanging on the wall Carefully read the following imformation before attempting to hang the unit on a wall. Take note of the various limitations specified in this section. Mount the unit so that twisting, bending, or any other warping does not exceed 4 mm. Shaded areas indicate attachment points for mounting hardware. : Thermometer (temperature measurement point) 1470 A B 880 50 162 C 25 D D Operating temperature restrictions ✩ Standard single-unit installation Distance from wall (A) B 50 mm or less 300 mm or more 50 mm or more 100 mm or more C 300 mm or more 50 mm or more D 300 mm or more 50 mm or more Ambient temperature 0 °C to 35 °C 0 °C to 40 °C ✩ Requirements when used with PDP-S55-LR speaker system When installed as a single unit, all requirements are the same as those listed above for horizontal/ vertical, left/right reverse installations. However, the figures listed above indicate the distance between the speakers and the wall. Note Different temperature restrictions apply to the PDK-WM03. Refer to "4.5 Wall Mount Unit PDK-WM03" (pg. 68). For a wall-mount installation, allow adequate space (a clearance of 300 mm or more) above, below, and to each side of the panel. 26