Pioneer 607CMX Technical Manual - Page 99
Normal Operating Mode, 2 Normal Operation Mode
UPC - 012562824413
View all Pioneer 607CMX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Normal Operating Mode 5.2 Normal Operation Mode 5.2.1 About normal operation mode The following controls are possible in the normal operation mode. 1 Switching input • Pressing the [INPUT1] to [INPUT5] buttons on the remote control changes the input that setting. • Pressing the [INPUT] button on the main-control panel changes the input each time the button is pressed. Note When a PDA-5003 or a PDA-5004 is not installed, the input switches only between INPUT1 and INPUT2. 2 Switching the screen size • Each time the [SCREEN SIZE] button on the remote control or main-control panel is pressed, the display screen size changes. When reproducing a PC signal 3 DOT BY DOT 3 4: 3 3 FULL When reproducing a video signal (signal other than a PC signal) # (Applicable only when a PDA-5003 or a PDA- 5004 is installed.) 3 4:3 3 FULL 3 WIDE 14:9 2 2.35:1 2 ZOOM 2 Note • The reproducible screen size changes according to the input signal. Refer to the section 5.1.3, "List of Input Correspondence Signals" (pg. 80). • To select 'Underscan', set the PRO USE option in the integrator mode. When this display is to be used for commercial use or for public viewing, such as in a coffee shop or hotel, reducing or enlarging the screen by using the screen-size-switching function could infringe on the copyright of the creator according to copyright laws. 2 Display call A Pressing the [DISPLAY] button on the remote control or main-control panel displays the current input function, horizontal and vertical frequency of the input signal, the type of signal, and the screen size (DISPLAY CALL 1). Note The displayed horizontal and vertical frequencies are measured values. Measurement errors are possible. B Pressing the [DISPLAY] button on the remote control or main-control panel again for three seconds or more when the display described in A above is displayed, cause various settings and internal temperature to be displayed as shown below (DISPLAY CALL 2). PDP-607CMX SERIAL NO. LOT D AT E HOUR METER T E M P E R AT U R E OSD BAUD RATE FAN CONTROL ID NO. SET COLOR MODE I N F O R M AT I O N :ABCDEFGHIJKLMN 001A001K :001A001X :00239H :+25 :ON :9600BPS :AUTO :ALL :NORMAL SERIAL NO.: Displays the serial number of the product LOT/DATE: Displays the manufacturing control number HOUR METER: Displays the conduction time for the product TEMPERATURE: Displays the outside air temperature that is measured by a temperature sensor located in the product Other items: Displays the settings in the integrator mode Note When the displayed temperature is high, the panel shuts down. However, the display itself should always be used as an indicator. 99