Sony HDWM2000/20 Operation Manual - Page 32
Reference Sync Signals, 3-2-1 Selecting Reference Signal Depending on Operational Status
View all Sony HDWM2000/20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
3-2 Reference Sync Signals Chapter 3 Preparations This section describes how reference signals for the video output signals and servo system are selected. The output from the internal reference video signal generator is supplied to the output video signal and servo circuits as a reference signal. 3-2-1 Selecting Reference Signal Depending on Operational Status The reference signal selection switches automatically between REF and INPUT depending on the menu settings and the operating status of the unit, as shown in the following table. F2 (OUTREF) setting - REF INPUT REF INPUT Menu item 309 setting Menu item 334 setting Unit's operational status a) EXT - EE PB EDIT REC INPUT EE PB EDIT REC AUTO1 NORMAL EE PB EDIT REC INPUT EE PB EDIT REC - EE PB EDIT REC AUTO2 NORMAL EE PB EDIT REC INPUT EE PB EDIT REC - EE PB EDIT REC Reference signal setting REF INPUT REF INPUT REF INPUT REF INPUT REF INPUT a) EE: In E-E mode PB: Playing back (normal playback, jog mode, shuttle mode, variable-speed mode, and also stop mode) EDIT: Edit preset enabled REC: Recording 3-2 Chapter 3 Preparations