Casio QT 6600 Reference Manual - Page 90

Manager Operation

Page 90 highlights

Manager Operation 3. Manager operation This section describes manager operations (such as machine initialization, IPL, manager functions etc.) of QT-6600. 3-1. Machine initialization There are three different types of initialization such as INIT, FC, and INIT2. INIT; Machine initialization, all program and total data are reset. FC; Flag clear, all program and total data are remained, only the current transaction data are reset. INIT2; Machine initialization 2, all program data are remained, only total data are reset. The procedures of machine initialization are described in the chapter 1 of the programming manual. The required init code are listed below. Operation Init Flag clear Init2 Init code 00020000 00010000 00040000 00050000 00060000 00080000 No need 8888888888 Meaning for the U.S. for other area (default descriptors are initialized in English) for other area (default descriptors are initialized in German) for other area (default descriptors are initialized in French) for other area (default descriptors are initialized in Spanish) Arabic (default descriptors are initialized in English) * See the "INIT code" section to notice the detail information. 3-1-1. INIT Initialization process is as follows: Start Input Init code (see above) Hardware reset All RAM reset Inline ID definition File creation 1 Initialization operation Input date/time, ID etc. File creation 2 Revise terminal connection table Receiving program from other terminal or CF card Initialization result to E-journal End 3-1-2. Flag clear Flag clear process is as follows: Start Hardware reset Initialize work area/ buffers/flags Menu selection FC/Init2 R-90 Initialization result to E-journal Init 2 End

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240

R-90
Manager Operation
3.
Manager operation
This section describes manager operations (such as machine initialization, IPL, manager
functions etc.) of QT-6600.
3-1. Machine initialization
There are three different types of initialization such as INIT, FC, and INIT2.
INIT; Machine initialization, all program and total data are reset.
FC; Flag clear, all program and total data are remained, only the current transaction data
are reset.
INIT2; Machine initialization 2, all program data are remained, only total data are reset.
The procedures of machine initialization are described in the chapter 1 of the programming
manual. The required init code are listed below.
3-1-2.
Flag clear
Flag clear process is as follows:
3-1-1.
INIT
Initialization process is as follows:
Start
End
Hardware reset
All RAM reset
Inline ID definition
File creation 1
File creation 2
Initialization result
to E-journal
Revise terminal
connection table
Input Init code
(see above)
Initialization operation
Input date/time, ID etc.
Receiving program
f
rom other terminal or
CF card
Start
Hardware reset
Initialize work area/
buffers/flags
Initialization result
to E-journal
End
Menu selection
FC/Init2
Init 2
Operation
Init code
Meaning
00020000
for the U.S.
00010000
for other area (default descriptors are initialized in English)
Init
00040000
for other area (default descriptors are initialized in German)
00050000
for other area (default descriptors are initialized in French)
00060000
for other area (default descriptors are initialized in Spanish)
00080000
Arabic (default descriptors are initialized in English)
Flag clear
No need
Init2
8888888888
* See the
INIT code
section to notice the detail information.