Dell Brocade 6520 Fabric OS Troubleshooting and Diagnostics Guide v7.1.0 - Page 123

Displaying a summary of port errors for a switch, TABLE 21

Page 123 highlights

Port information 10 Displaying a summary of port errors for a switch 1. Connect to the switch and log in as admin. 2. Enter the portErrShow command. Refer to the Fabric OS Command Reference for additional portErrShow command information. switch:admin> porterrshow frames enc crc crc too too bad enc disc link loss loss frjt fbsy tx rx in err g_eof shrt long eof out c3 fail sync sig 0: 665k 7.0k 0 0 0 0 0 0 6 0 0 1 2 0 0 1: 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 2: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 3: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 4: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 5: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 6: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 7: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 8: 78 60 0 0 0 0 0 0 7 0 0 3 6 0 0 9: 12 4 0 0 0 0 0 0 3 0 0 1 2 0 0 10: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 11: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 12: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 13: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 14: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 15: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 16: 665k 7.4k 0 0 0 0 0 0 6 0 0 1 2 0 0 17: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 18: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 19: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 20: 6.3k 6.6k 0 0 0 0 0 0 7 0 0 1 2 0 0 21: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 22: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 23: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 24: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 25: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 26: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 27: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 28: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 29: 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 30: 664k 6.7k 0 0 0 0 0 0 6 0 0 1 2 0 0 31: 12 4 0 0 0 0 0 0 3 0 0 1 2 0 0 (output truncated) The portErrShow command output provides one output line per port. See Table 21 for a description of the error types. TABLE 21 Error summary description Error type Description frames tx frames rx enc in crc err crc g_eof Frames transmitted Frames received Encoding errors inside frames Frames with CRC errors CRC errors that occur on frames with good end-of-frame delimiters. Fabric OS Troubleshooting and Diagnostics Guide 107 53-1002751-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

Fabric OS Troubleshooting and Diagnostics Guide
107
53-1002751-01
Port information
10
Displaying a summary of port errors for a switch
1.
Connect to the switch and log in as admin.
2.
Enter the
portErrShow
command. Refer to the
Fabric OS Command Reference
for additional
portErrShow command information.
switch:admin>
porterrshow
frames
enc
crc
crc
too
too
bad
enc disc link loss loss frjt fbsy
tx
rx
in
err g_eof shrt long
eof
out
c3 fail sync
sig
============================================================================
0:
665k 7.0k
0
0
0
0
0
0
6
0
0
1
2
0
0
1:
0
0
0
0
0
0
0
0
0
0
0
0
2
0
0
2:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
3:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
4:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
5:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
6:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
7:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
8:
78
60
0
0
0
0
0
0
7
0
0
3
6
0
0
9:
12
4
0
0
0
0
0
0
3
0
0
1
2
0
0
10:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
11:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
12:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
13:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
14:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
15:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
16:
665k 7.4k
0
0
0
0
0
0
6
0
0
1
2
0
0
17:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
18:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
19:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
20:
6.3k 6.6k
0
0
0
0
0
0
7
0
0
1
2
0
0
21:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
22:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
23:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
24:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
25:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
26:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
27:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
28:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
29:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
30:
664k 6.7k
0
0
0
0
0
0
6
0
0
1
2
0
0
31:
12
4
0
0
0
0
0
0
3
0
0
1
2
0
0
(output truncated)
The
portErrShow
command output provides one output line per port. See
Table 21
for a description
of the error types.
TABLE 21
Error summary description
Error type
Description
frames tx
Frames transmitted
frames rx
Frames received
enc in
Encoding errors inside frames
crc err
Frames with CRC errors
crc g_eof
CRC errors that occur on frames with good end-of-frame delimiters.