Dell Brocade G620 Brocade 8.0.1 Fabric OS Troubleshooting and Diagnostics Guid - Page 61

Blade types, Firmware versions

Page 61 highlights

Firmware Download Errors Downgrade is not allowed because Monitoring and Alerting Policy Suite (MAPS) is enabled. Please disable MAPS using "mapsconfig --disable" before proceeding. Downgrade to pre-7.4 Fabric OS versions is not allowed. Please configure TACACS+ keys of length in the range (8-40) characters using aaaconfig CLI {Usage: aaaconfig --change -conf tacacs+ [-s ], before performing a firmware downgrade. Downgrade is not allowed because ICL ports are configured as EX-ports.Please use "portcfgshow" to view the ICL EX ports and use "portcfgexport" to disable the EX feature on those ports before downgrading. The following example shows feature-related messages that you may see if you were downgrading from Fabric OS v7.3.0 to v7.2.x : Downgrade to selected version is not allowed because few ports are configured with Longdistance -buffers option. Please remove the configuration using "portcfglongdistance L0" CLI or change the configuration with -distance option. Downgrade is not allowed because Location ID is configured. Please use "configure" command to clear Location ID. Downgrade is not allowed because switch is in AG mode and D-Ports are configured. Please use "switchshow" to view the D-port list and use "portcfgdport --disable " to disable it before downgrading. Downgrade is not allowed because R-RDY flow control ports are configured as D-Ports. Please use "portdporttest --show all" to view the port list and "portcfgdport --disable" to disable before downgrading. Downgrade is not allowed because D-Port is configured with DWDM mode. Please use "portcfgshow" to view the port list and "portcfgdport --enable" to reset DWDM mode before downgrading. Downgrade is not allowed because ICL ports are configured as D-Ports. Please use "switchshow" to view the D-port list and use "portcfgdport --disable " to disable it before downgrading. Downgrade is not allowed because one or more ports have credit recovery enabled. Please use "portcfgcreditrecovery --disable" command to disabled credit recovery. Downgrade is not allowed because one or more ports have FEC enabled. Please use "portcfgfec --disable" command to disabled FEC. Blade types Where blades are incompatible with a firmware download, they must be removed or powered off before a firmware download begins, as noted in the following message. Message Probable cause and recommended action The FC10-6 (type 39) blade is not supported by the target firmware. Please use slotshow to find out which slot it is in and remove it first. The firmware download operation was attempting to upgrade a system to Fabric OS v7.4.0 with one or more of the Brocade FC10-6 blades (blade ID 39) in the system. The Brocade FC10-6 blades are not supported on firmware v7.4.0, so the firmware download operation failed. Use the slotShow command to display which slots the Brocade FC10-6 blades occupy. Physically remove the blades from the chassis, or use the micro-switch to turn the blade off. Retry the firmware download operation. Firmware versions The system messages in this section refer to differences between the current firmware and the firmware you are applying to the switch. ATTENTION Brocade does not support upgrades from more than one previous release. For example, upgrading from Fabric OS v7.3.0 to v7.4.0 is supported, but upgrading from Fabric OS v7.2.0 or a previous release directly to v7.4.0 is not. In other words, upgrading a switch from Fabric OS v7.2.0 to v7.4.0 is a two-step process: first upgrade to v7.3.0, and then upgrade to v7.4.0. If you are running a pre-Fabric OS v7.0.0 version, first you must upgrade to v7.0.0, then to v7.1.0, then to v7.2.0, then to v7.3.0, and finally to v7.4.0. Brocade Fabric OS Troubleshooting and Diagnostics Guide 53-1004126-01 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Downgrade is not allowed because Monitoring and Alerting Policy Suite (MAPS) is enabled.
Please disable MAPS using "mapsconfig --disable" before proceeding.
Downgrade to pre-7.4 Fabric OS versions is not allowed.
Please configure TACACS+ keys of length in the range (8-40) characters using aaaconfig CLI
{Usage: aaaconfig --change <server> -conf tacacs+ [-s <secret>],
before performing a firmware downgrade.
Downgrade is not allowed because ICL ports are configured as EX-ports.Please
use "portcfgshow" to view the ICL EX ports and use "portcfgexport" to disable
the EX feature on those ports before downgrading.
The following example shows feature-related messages that you may see if you were downgrading from Fabric OS v7.3.0 to v7.2.
x
:
Downgrade to selected version is not allowed because few ports are configured
with Longdistance -buffers option. Please remove the configuration using
"portcfglongdistance L0" CLI or change the configuration with -distance option.
Downgrade is not allowed because Location ID is configured.
Please use "configure" command to clear Location ID.
Downgrade is not allowed because switch is in AG mode and D-Ports are configured.
Please use "switchshow" to view the D-port list and use "portcfgdport
--disable <port_no>" to disable it before downgrading.
Downgrade is not allowed because R-RDY flow control ports are configured as D-Ports.
Please use "portdporttest --show all" to view the port list and
"portcfgdport --disable" to disable before downgrading.
Downgrade is not allowed because D-Port is configured with DWDM mode.
Please use "portcfgshow" to view the port list and "portcfgdport --enable"
to reset DWDM mode before downgrading.
Downgrade is not allowed because ICL ports are configured as D-Ports.
Please use "switchshow" to view the D-port list and use
"portcfgdport --disable <port_no>" to disable it before downgrading.
Downgrade is not allowed because one or more ports have credit recovery enabled.
Please use "portcfgcreditrecovery --disable" command to disabled credit recovery.
Downgrade is not allowed because one or more ports have FEC enabled.
Please use "portcfgfec --disable" command to disabled FEC.
Blade types
Where blades are incompatible with a firmware download, they must be removed or powered off before a firmware download begins, as
noted in the following message.
Message
The FC10-6 (type 39) blade is not supported by the target firmware.
Please use slotshow to find out which slot it is in and remove it first.
Probable cause and recommended action
The firmware download operation was attempting to upgrade a system to
Fabric OS v7.4.0 with one or more of the Brocade FC10-6 blades (blade
ID 39) in the system. The Brocade FC10-6 blades are not supported on
firmware v7.4.0, so the firmware download operation failed.
Use the
slotShow
command to display which slots the Brocade FC10-6
blades occupy. Physically remove the blades from the chassis, or use the
micro-switch to turn the blade off. Retry the firmware download operation.
Firmware versions
The system messages in this section refer to differences between the current firmware and the firmware you are applying to the switch.
ATTENTION
Brocade does not support upgrades from more than one previous release. For example, upgrading from Fabric OS v7.3.0 to
v7.4.0 is supported, but upgrading from Fabric OS v7.2.0 or a previous release directly to v7.4.0 is not. In other words,
upgrading a switch from Fabric OS v7.2.0 to v7.4.0 is a two-step process: first upgrade to v7.3.0, and then upgrade to v7.4.0. If
you are running a pre-Fabric OS v7.0.0 version, first you must upgrade to v7.0.0, then to v7.1.0, then to v7.2.0, then to v7.3.0,
and finally to v7.4.0.
Firmware Download Errors
Brocade Fabric OS Troubleshooting and Diagnostics Guide
53-1004126-01
61