Dell Brocade G620 Brocade 8.0.1 Fabric OS Troubleshooting and Diagnostics Guid - Page 89

Link errors, Tx/Rx errors, on for more information on changing

Page 89 highlights

Diagnostic Features Link errors Once the frame is sent out of the port, the spinFab command monitors the link errors in the ASIC. If any of the error counters are nonzero, spinFab reports an error and the test fails on the port. ERROR: DIAG ERRSTAT spinfab, pass 6, Pt0/17(7) Ch0/7 CRC_err Error Counter is 109738997 sb 0, ERROR: DIAG ERRSTAT spinfab, pass 1, Pt0/3(33) Ch0/33 Enc_in Error Counter is 32 sb 0, ERROR: DIAG ERRSTAT spinfab, pass 1, Pt0/3(33) Ch0/33 Enc_out Error Counter is 187725412 sb 0, ERROR: DIAG ERRSTAT spinfab, pass 1, Pt0/3(33) Ch0/33 TruncFrm Error Counter is 32 sb 0, ERROR: DIAG ERRSTAT spinfab, pass 1, Pt0/3(33) Ch0/33 FrmTooLong Error Counter is 32 sb 0, ERROR: DIAG ERRSTAT spinfab, pass 1, Pt0/3(33) Ch0/33 BadOrdSet Error Counter is 32 sb 0, ERROR: DIAG ERRSTAT spinfab, pass 1, Pt0/3(33) Ch0/33 BadEOF Error Counter is 1 sb 0, ERROR: DIAG ERRSTAT spinfab, pass 1, Pt0/3(33) Ch0/33 DiscC3 Error Counter is 32 sb 0, If you receive any of the link errors, follow the suggested debugging procedures: ∙ The spinFab command does not clear any existing error counters before running the test. You should first clear all error counters and rerun the spinFab command. ∙ Verify that the link comes up by enabling and disabling the local or remote ports. ∙ Verify that the source of the error is either the local port or the remote port. This can be done by monitoring the port statistics on both ends simultaneously. Refer to Displaying the port statistics on page 91 for more information on how to display the statistics for a port. ∙ Verify that the cables and SFPs are inserted properly. Remove and insert them again on both ends. ∙ Verify that the failing local port is working when connected to another remote port. Similarly, check whether the failing remote port is working when connected to another local port. ∙ Once the fault is isolated on either the local port or the remote port, replace the cable and SFPs connected to the local port and the remote ports. ∙ In case of loopback ports, change the loopback plug. Refer to Marginal links on page 41 for more information on changing the loopback plug. ∙ Further isolation can be done by running the portLoopbackTest command (Offline test) on the failing port to check whether the blade internal ports are having some problems. - The -lb_mode 1 operand verifies that the SFP is working within normal operating parameters. The use of this operand requires that loopback cables are connected. - The -lb_mode 2 verifies that the ASIC port is working within normal operating parameters. The use of this operand does not require any loopback cables. Tx/Rx errors The following errors are seen when the port fails to transmit or receive the frames. ERROR: DIAG PORTSTOPPED spinfab:spinfab, 0 nMegs, Pt7/2(2) Ch0/2 No Longer Transmitting, FTX Counter Stuck at 116295726, ERROR: DIAG TIMEOUT spinfab:spinfab, pass 2, Pt0/17(7) Ch0/7 Receive Error/Timeout Brocade Fabric OS Troubleshooting and Diagnostics Guide 53-1004126-01 89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Link errors
Once the frame is sent out of the port, the
spinFab
command monitors the link errors in the ASIC. If any of the error counters are non-
zero,
spinFab
reports an error and the test fails on the port.
ERROR: DIAG ERRSTAT spinfab, pass 6,
Pt0/17(7) Ch0/7 CRC_err Error Counter is 109738997 sb 0,
ERROR: DIAG ERRSTAT spinfab, pass 1,
Pt0/3(33) Ch0/33 Enc_in Error Counter is 32 sb 0,
ERROR: DIAG ERRSTAT spinfab, pass 1,
Pt0/3(33) Ch0/33 Enc_out Error Counter is 187725412 sb 0,
ERROR: DIAG ERRSTAT spinfab, pass 1,
Pt0/3(33) Ch0/33 TruncFrm Error Counter is 32 sb 0,
ERROR: DIAG ERRSTAT spinfab, pass 1,
Pt0/3(33) Ch0/33 FrmTooLong Error Counter is 32 sb 0,
ERROR: DIAG ERRSTAT spinfab, pass 1,
Pt0/3(33) Ch0/33 BadOrdSet Error Counter is 32 sb 0,
ERROR: DIAG ERRSTAT spinfab, pass 1,
Pt0/3(33) Ch0/33 BadEOF Error Counter is 1 sb 0,
ERROR: DIAG ERRSTAT spinfab, pass 1,
Pt0/3(33) Ch0/33 DiscC3 Error Counter is 32 sb 0,
If you receive any of the link errors, follow the suggested debugging procedures:
The
spinFab
command does not clear any existing error counters before running the test. You should first clear all error
counters and rerun the
spinFab
command.
Verify that the link comes up by enabling and disabling the local or remote ports.
Verify that the source of the error is either the local port or the remote port. This can be done by monitoring the port statistics
on both ends simultaneously. Refer to
Displaying the port statistics
on page 91 for more information on how to display the
statistics for a port.
Verify that the cables and SFPs are inserted properly. Remove and insert them again on both ends.
Verify that the failing local port is working when connected to another remote port. Similarly, check whether the failing remote
port is working when connected to another local port.
Once the fault is isolated on either the local port or the remote port, replace the cable and SFPs connected to the local port and
the remote ports.
In case of loopback ports, change the loopback plug. Refer to
Marginal links
on page 41 for more information on changing the
loopback plug.
Further isolation can be done by running the
portLoopbackTest
command (Offline test) on the failing port to check whether the
blade internal ports are having some problems.
The
-lb_mode 1
operand verifies that the SFP is working within normal operating parameters. The use of this operand
requires that loopback cables are connected.
The
-lb_mode 2
verifies that the ASIC port is working within normal operating parameters. The use of this operand does
not require any loopback cables.
Tx/Rx errors
The following errors are seen when the port fails to transmit or receive the frames.
ERROR: DIAG PORTSTOPPED spinfab:spinfab, 0 nMegs,
Pt7/2(2) Ch0/2 No Longer Transmitting, FTX Counter Stuck at 116295726,
ERROR: DIAG TIMEOUT spinfab:spinfab, pass 2,
Pt0/17(7) Ch0/7 Receive Error/Timeout
Diagnostic Features
Brocade Fabric OS Troubleshooting and Diagnostics Guide