Dell PowerConnect Brocade M6505 Brocade 7.1.0 Access Gateway Administrator's G - Page 72

Adding a preferred secondary N_Port optional,

Page 72 highlights

3 Failover policy Example 1 Hosts Host_1 Access Gateway F_1 Host_2 F_2 N_1 Host_3 F_3 N_2 Host_4 F_4 Host_5 F_5 N_3 Host_6 F_6 N_4 Host_7 F_7 Fabric Edge Switch (Switch_A) F_A1 F_A2 Edge Switch (Switch_B) F_B1 Example 2 Hosts Host_1 Host_2 Host_3 Host_4 Host_5 F_B2 Host_6 Host_7 Access Gateway F_1 F_2 N_1 F_3 N_2 F_4 F_5 N_3 F_6 N_4 F_7 Fabric Edge Switch (Switch_A) F_A1 F_A2 Edge Switch (Switch_B) F_B1 F_B2 Host_8 F_8 FIGURE 11 Failover behavior Host_8 F_8 Legend Physical connection Mapped online Failover route online Original mapped route (offline) Adding a preferred secondary N_Port (optional) F_Ports automatically fail over to any available N_Port. Alternatively, you can specify a preferred secondary N_Port in case the primary N_Port fails. If the primary N_Port goes offline, the F_Ports fail over to the preferred secondary N_Port (if it is online), then re-enable. If the secondary N_Port is offline, the F_Ports will disable. Define the preferred secondary N_Ports per F_Port. For example, if two F_Ports are mapped to a primary N_Port, you can define a secondary N_Port for one of those F_Ports and not define a secondary N_Port for the other F_Port. F_Ports must have a primary N_Port mapped before a secondary N_Port can be configured. 1. Connect to the switch and log in using an account assigned to the admin role. 2. Enter the ag --prefset command with the "F_Port1;F_Port2; ..." N_Port options to add the preferred secondary F_Ports to the specified N_Port. The F_Ports must be enclosed in quotation marks and the port numbers must be separated by a semicolon, as shown in the following example. switch:admin> ag --prefset "3;9" 4 Preferred N_Port is set successfully for the F_Port[s] NOTE Preferred mapping is not allowed when Automatic Login Balancing mode is enabled for a port group. All N_Ports are the same when Automatic Login Balancing mode is enabled. 52 Access Gateway Administrator's Guide 53-1002743-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

52
Access Gateway Administrator’s Guide
53-1002743-01
Failover policy
3
FIGURE 11
Failover behavior
Adding a preferred secondary N_Port (optional)
F_Ports automatically fail over to any available N_Port. Alternatively, you can specify a preferred
secondary N_Port in case the primary N_Port fails. If the primary N_Port goes offline, the F_Ports
fail over to the preferred secondary N_Port (if it is online), then re-enable. If the secondary N_Port is
offline, the F_Ports will disable. Define the preferred secondary N_Ports per F_Port. For example, if
two F_Ports are mapped to a primary N_Port, you can define a secondary N_Port for one of those
F_Ports and not define a secondary N_Port for the other F_Port. F_Ports must have a primary
N_Port mapped before a secondary N_Port can be configured.
1.
Connect to the switch and log in using an account assigned to the admin role.
2.
Enter the
ag
--
prefset
command with the “
F_Port1;F_Port2; ...” N_Port
options to add the
preferred secondary F_Ports to the specified N_Port.
The F_Ports must be enclosed in quotation marks and the port numbers must be separated by
a semicolon, as shown in the following example.
switch:admin>
ag --prefset "3;9" 4
Preferred N_Port is set successfully for the F_Port[s]
NOTE
Preferred mapping is not allowed when Automatic Login Balancing mode is enabled for a port group.
All N_Ports are the same when Automatic Login Balancing mode is enabled.
F_A2
Hosts
Access Gateway
Edge Switch
Fabric
(Switch_A)
F_4
F_3
F_2
F_1
N_1
F_A1
N_3
F_B1
Host_1
Host_2
Host_3
Host_4
F_5
Host_5
F_6
Host_6
F_7
Host_7
F_8
Host_8
Edge Switch
(Switch_B)
N_4
F_B2
N_2
Legend
Physical connection
Mapped online
Failover route online
Original mapped route
(offline)
Example 1
F_A2
Hosts
Access Gateway
Edge Switch
Fabric
(Switch_A)
F_4
F_3
F_2
F_1
N_1
F_A1
N_3
F_B1
Host_1
Host_2
Host_3
Host_4
F_5
Host_5
F_6
Host_6
F_7
Host_7
F_8
Host_8
Edge Switch
(Switch_B)
N_4
F_B2
Example 2
N_2