Dell PowerEdge M610x Fabric OS Command Reference Manual Supporting Fabric - Page 106
current logical switch are not displayed. This is change from v6.3.0, where
View all Dell PowerEdge M610x manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
2 bottleneckMon -span seconds Specifies the total duration in seconds covered in the output. When a port is specified with the --show command, the maximum span is 10800 seconds (3 hours). When a wildcard (*) is specified, the maximum span is defined such that the value of -span divided by the value of the interval cannot exceed 30. The span value must be greater than 0. The default value is 10 seconds. History data are maintained for a maximum of three hours per port, so the span can be 10800 seconds at most. When the show command is issued for all ports (*), the maximum duration is defined such that the value of -span divided by the value of the interval cannot exceed 30. -refresh Refreshes the display to continuously update with fresh data at a certain rate. The refresh rate is equal to the number of seconds specified in the interval. -congestion | -latency Restricts the display to congestion or latency data. If neither is specified, the command displays combined statistics for both types of bottlenecks --status Displays the details of the Bottleneck Detection configuration for the current (logical) switch. Refer to the command description section for an explanation of the displays. If virtual fabrics are enabled, ports not belonging to the current logical switch are not displayed. This is change from v6.3.0, where the output of --status included ports that did not belong to the current logical switch. --help Displays the command usage. Examples To enable bottleneck monitoring on the switch without alerts (statistics collected with default parameters are still available for viewing): switch:admin> bottleneckmon --enable To enable bottleneck monitoring on the switch with alerts using default values for thresholds and time (preferred use case): switch:admin> bottleneckmon --enable -alert To customize congestion bottleneck monitoring on a port range after default alerts are enabled switch-wide: switch:admin> bottleneckmon --enable -alert switch:admin> bottleneckmon --config -alert -cthresh .5 -time 240 1-15 To disable bottleneck monitoring on a specified port: switch:admin> bottleneckmon --exclude 2/4 To disable bottleneck monitoring on all ports of a chassis: switch:admin> bottleneckmon --disable 74 Fabric OS Command Reference 53-1001764-02