Dell PowerEdge M610x Fabric OS Command Reference Manual Supporting Fabric - Page 532
To display the logical switch configuration for GbE ports only in the following example, all GbE ports
![]() |
View all Dell PowerEdge M610x manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 532 highlights
2 lsCfg To assign ports to a logical switch: switch:admin> lscfg --config 2 -port 10-12 This operation requires that the affected ports be disabled. Would you like to continue [y/n]?: y Making this configuration change. Please wait... Configuration change successful. Please enable your ports/switch when you are ready to continue. To assign ports to a logical switch without confirmation: switch:admin> lscfg --config 2 -port 0-4 -force Configuration change successful. Making this configuration change. Please wait... Please enable your ports/switch when you are ready to continue. To display the logical switch configuration for :FC ports only: switch:admin> lscfg --show Created switches: 128(ds) 1(bs) 2 Port 0 1 2 3 4 5 6 7 8 9 FID 1| 1| 1| 1| 1| 1| 1| 1| 2| 2| Port 10 11 12 13 14 15 16 17 18 19 FID 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | Port 20 21 22 23 24 25 26 27 28 29 FID 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | Port 30 31 32 33 34 35 36 37 38 39 FID 128 | 128 | 128 | 2 | 2 | 2 | 128 | 128 | 128 | 128 | To display the logical switch configuration for GbE ports only (in the following example, all GbE ports are in logical switch 2): switch:admin> lscfg --show -ge Created switches: (ds) 2(bs) 1 Slot 1 2 3 4 5 6 7 8 Port 0 | | 2| | | | | | | 1 | | 2| | | | | | | 2 | | 2| | | | | | | 3 | | 2| | | | | | | 4 | | 2| | | | | | | 5 | | 2| | | | | | | 6 | | 2| | | | | | | 7 | | 2| | | | | | | 8 | | 2| | | | | | | 9 | | 2| | | | | | | 10 | | 2| | | | | | | 11 | | 2| | | | | | | 500 Fabric OS Command Reference 53-1001764-02
![](/manual_guide/products/dell-8-fabric-os-command-reference-manual-supporting-fabric-155f671/532.png)