Code Text Causes Corrective Actions E1211 RAID Controller battery failure. Check battery. RAID battery is either missing, bad, or unable to recharge due to thermal issues. Reseat the RAID battery connector. See "Installing the RAID Battery" on page 147 and "Troubleshooting System Cooling Problems" on page 180. E1216 3.3V Regulator failure. Reseat PCIe cards. 3.3V voltage regulator failed. Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 189. E1219 Disk Backplane power failure. Check BP power cable. Storage backplane voltage regulator has failed. Remove and reseat the backplane. If the problem persists, see "Getting Help" on page 203. E1222 CPU # VCACHE Regulator failure. Contact support. Processor voltage regulator failed. Reseat the processor(s). See "Troubleshooting the Processors" on page 190. If the problem persists, see "Getting Help" on page 203. E122C CPU Power A power fault was detected Remove AC power to the Fault. Power when powering up the system for 10 seconds and cycle AC. processor(s). restart the system. If the problem persists, see "Getting Help" on page 203. E122E On-board regulator failed. Call support. One of the on-board voltage Remove AC power to the regulators failed. system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 203. 26 About Your System