W1102 Mem Voltage, Check PSU - power requirements
View all Dell PowerEdge R910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Code Text Causes Corrective Actions W1101 CPU VCACHE Regulator temp exceeding range. Check fans. The regulator temperature has reached a point outside of the allowed range. See "Troubleshooting System Cooling Problems" on page 180. If the problem persists, see "Getting Help" on page 203. W1102 Mem Voltage Regulator temp exceeding range. Check fans The regulator temperature has reached a point outside of the allowed range. See "Troubleshooting System Cooling Problems" on page 180. If the problem persists, see "Getting Help" on page 203. W1228 RAID Controller battery capacity < 24hr. Warns predictively that the RAID battery has less than 24 hours of charge left. Allow RAID battery to charge to greater than 24 hours of sustained charge. If problem persists, replace the RAID battery. See "Installing the RAID Battery" on page 147. W1627 Power The system configuration required > requires more power than PSU wattage. what the power supply can Check PSU and provide. config. Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. W1628 Performance degraded. Check PSU and system configuration. The system configuration requires more power than what the power supply can provide, but it can boot if throttled. Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. 40 About Your System