E141C Unsupported, CPU or BIOS - specification
View all Dell PowerEdge R910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Code Text Causes Corrective Actions E1313 Fan redundancy lost. Check fans. The system is no longer fan Check LCD for additional redundant. Another fan scrolling messages. See failure would put the system "Troubleshooting a Fan" at risk of over-heating. on page 180. E1314 Critical system All fans have been removed from system. cooling loss. Check fans. Ensure that the fans are properly installed. See "Troubleshooting a Fan" on page 180. E1410 System Fatal Error detected. A fatal system error has been Check LCD for additional detected. scrolling messages. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 203. E1414 CPU # temp Specified processor is out of Ensure that the processor exceeding acceptable temperature heat sinks are properly range. Check range. installed. See CPU heatsink. "Troubleshooting the Processors" on page 190 and "Troubleshooting System Cooling Problems" on page 180. E1418 CPU # not detected. Check CPU is seated properly. Specified processor is Ensure that the specified missing or bad, and the processor is properly system is in an unsupported installed. See configuration. "Troubleshooting the Processors" on page 190. E141C Unsupported Processors are in an CPU configur- unsupported configuration. ation. Check CPU or BIOS revision. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in your system's Getting Started Guide. 28 About Your System