Dell PowerEdge R910 Hardware Owner's Manual - Page 43
Check PSU and, Alert! System - memory upgrade
View all Dell PowerEdge R910 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Message Causes Corrective Actions Alert! Power required exceeds PSU wattage. Check PSU and system configuration. Alert! Continuing system boot accepts the risk that system may power down without warning. The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with the High Output power supplies to use the components. See "Power Supplies" on page 154. Alert! Redundant memory disabled! Memory configuration does not support redundant memory. Memory Mirroring was enabled in the system setup program, but the current configuration does not support redundant memory. A memory module may be faulty. Check the memory modules for failure. See "Troubleshooting System Memory" on page 181. Reset the memory setting, if appropriate. See "Using the System Setup Program and UEFI Boot Manager" on page 63. Alert! System fatal error during previous boot. An error caused the system to Check other system reboot. messages for additional information for possible causes. BIOS MANUFACTURING MODE detected. MANUFACTURING MODE will be cleared before the next boot. System reboot required for normal operation. System is in manufacturing Reboot to take the system mode. out of manufacturing mode. About Your System 43