Fluke 1586A/2HC Product Manual - Page 24
Thermistor
View all Fluke 1586A/2HC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
1586A Users Manual PRT/RTD Temperature Accuracy Accuracy is for 4-wire 100 Ω nominal PRT/RTD, using medium or slow sample rate. When using 3-wire PRT/RTD add 0.039 °C to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.15 °C if using channels x01 through x20. When using the Fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient number by the temperature deviation and add to the accuracy specification. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor and characterization. Temperature −200 °C 0 °C 300 °C 600 °C DAQ-STAQ Module High-Capacity Module Fast Sample Rate 0.006 °C 0.01 °C 0.018 °C 0.026 °C 0.01 °C 0.015 °C 0.03 °C 0.045 °C add 0.01 °C add 0.01 °C add 0.01 °C add 0.01 °C T.C./ °C Outside 18 °C to 28 °C 0.0019 °C 0.0023 °C 0.0028 °C 0.0034 °C PRT/RTD Measurement Characteristics Range 0 Ω to 400 Ω 400 Ω to 4 kΩ Temperature Display Resolution Slow / Medium Sample Rate Fast Sample Rate 0.001 °C 0.01 °C 0.001 °C 0.01 °C Source Current ±1 mA 0.1 mA Thermistor Temperature Range 200 °C to 400 °C (depending on the sensor) Resistance Range 0 Ω to 1 MΩ Thermistor Resistance Accuracy Accuracy is given as ± (% of measurement + Ω). The basic accuracy specification is for 4-wire thermistor, slow sample rate. When using medium or fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. For 2-wire thermistor add 0.02 Ω internal resistance if using Channel 1 or 1.5 Ω if using channels x01 through x20, and add external lead wire resistance. Range Slow Sample Rate Medium Sample Rate Rate Fast Sample Rate T.C./ °C Outside 18 °C to 28 °C 0 Ω to 2.2 kΩ 2.1 kΩ to 98 kΩ 95 kΩ to 1 MΩ 0.004 % + 0.2 Ω 0.004 % + 0.5 Ω 0.015 % + 5 Ω add 0.3 Ω add 0.5 Ω add 5 Ω add 1 Ω add 1.3 Ω add 13 Ω 0.0005 % + 0.05 Ω 0.0005 % + 0.1 Ω 0.001 % + 2 Ω 1-16 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664