Fluke 1586A/2HC Product Manual - Page 97

Record Measurement Data

Page 97 highlights

4 Scan/Monitor, Record, and Data Record Record The Record function saves the scan or DMM measurement results to a file that can be transferred to a PC for further evaluation. When the Product is recording data, the Record key is illuminated and "RECORDING" shows on the top of the display. Data is recorded for as long as the key is illuminated and "RECORDING" shows on the display. Note Scans can be completed without recording the results. In this scenario, the data is saved to temporary memory and will be overwritten the next time a scan is started or if the temporary memory becomes full (approximately 60,000 readings). Record Measurement Data For the Scan function, the behavior of the Record key is dependent on the Auto Recording setting in the Test Setup menu. If set to ON, the Product automatically records the scan data when the scan is started. If set to OFF, the user must manually push  to record scan data to file after the scan is started. Note Auto Recording is associated only with the Scan/Monitor function and does not work with the Measure/DMM function. To record a measurement, push  to start recording DMM or Measure data regardless of the Auto Recording setting in the Test Setup menu. Each time data is recorded, a new data folder is made with a unique timestamp so that it can be easily found and managed (see "Open a Data File on a PC"). Data files made from a scan are saved in the "scan" folder, DMM data files are saved in the "dmm" folder and, Measure data files are saved in the "meas" folder. Note Scan data, Measure data, or DMM data stored directly to the USB drive is not visible to the user through the Memory menu. However, the Memory menu shows the user how much memory is available on the USB drive. To manage the scan data files on the USB drive, connect the USB drive to a PC and open the folder named "scan", "meas", or "dmm". 4-19 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

Scan/Monitor, Record, and Data
Record
4
4-19
Record
The Record function saves the scan or DMM measurement results to a file that can be
transferred to a PC for further evaluation. When the Product is recording data, the
Record
key is illuminated and “RECORDING” shows on the top of the display. Data is
recorded for as long as the key is illuminated and “RECORDING” shows on the display.
Note
Scans can be completed without recording the results. In this scenario, the
data is saved to temporary memory and will be overwritten the next time a
scan is started or if the temporary memory becomes full (approximately
60,000 readings).
Record Measurement Data
For the Scan function, the behavior of the Record key is dependent on the Auto
Recording setting in the Test Setup menu. If set to ON, the Product automatically records
the scan data when the scan is started. If set to OFF, the user must manually push
to record scan data to file after the scan is started.
Note
Auto Recording is associated only with the Scan/Monitor function and does
not work with the Measure/DMM function. To record a measurement, push
to start recording DMM or Measure data regardless of the Auto
Recording setting in the Test Setup menu.
Each time data is recorded, a new data folder is made with a unique timestamp so that it
can be easily found and managed (see “Open a Data File on a PC”). Data files made from
a scan are saved in the “scan” folder, DMM data files are saved in the “dmm” folder and,
Measure data files are saved in the “meas” folder.
Note
Scan data, Measure data, or DMM data stored directly to the USB drive is
not visible to the user through the Memory menu. However, the Memory
menu shows the user how much memory is available on the USB drive. To
manage the scan data files on the USB drive, connect the USB drive to a
PC and open the folder named “scan”, “meas”, or “dmm”.
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com