Fluke 1586A/2HC Product Manual - Page 62

Current and Voltage Channels

Page 62 highlights

3 Input and Channel Configuration Channel Configuration 4. After the channel is configured, verify that the channel is configured properly and reading the input. For instructions, see "Verify a Channel" on page 3-14. Current and Voltage Channels Refer to Table 3-4 to configure a dc voltage or current channel. Note Ch001 can be set up for all measurements. ChX21 and ChX22 are the only channels that can be set up for current measurements. To expand the functionality of the Product, current sources can also be connected to ChX01 through ChX20 by the use of an accessory shunt resistor. See Chapter 2 for part number and ordering information. Table 3-4. Current and Voltage Channel Configuration 1 2 3 4 5 Item Function  DC voltage or DC current function selection. For voltage, set the voltage range to: Auto, 100 mV, 1 V, 10 V, or 50 V.  For current, set the current range to: Auto, 100 μA, 1 mA, 10mA, or 100 mA.  Input a custom alpha-numeric label to help identify the channel (optional).  Set an alarm for this channel (optional). See "HI and LO Channel Alarms" on page 3-31.  Apply Mx+B scaling to the measurement (optional). See "Mx+B Scaling" on page 3-30. hcn050.eps 3-19 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

Input and Channel Configuration
Channel Configuration
3
3-19
4.
After the channel is configured, verify that the channel is configured properly and
reading the input. For instructions, see “Verify a Channel” on page 3-14.
Current and Voltage Channels
Refer to Table 3-4 to configure a dc voltage or current channel.
Note
Ch001 can be set up for all measurements. ChX21 and ChX22 are the only
channels that can be set up for current measurements. To expand the
functionality of the Product, current sources can also be connected to
ChX01 through ChX20 by the use of an accessory shunt resistor. See
Chapter 2 for part number and ordering information.
Table 3-4. Current and Voltage Channel Configuration
1
2
3
4
5
hcn050.eps
Item
Function
DC voltage or DC current function selection.
For voltage, set the voltage range to: Auto, 100 mV, 1 V, 10 V, or 50 V.
For current, set the current range to: Auto, 100
μ
A, 1 mA, 10mA, or 100 mA.
Input a custom alpha-numeric label to help identify the channel (optional).
Set an alarm for this channel (optional). See “HI and LO Channel Alarms” on page 3-31.
Apply Mx+B scaling to the measurement (optional). See “Mx+B Scaling” on page 3-30.