HP 4550 Service Manual - Page 258

Blank or white s, The HVPS PCA is defective.

Page 258 highlights

Blank or white pages  Your software application is sending an extra page-eject command. • Check the software's printing configuration information.  There is a problem with the network configuration. Some sharing devices on networks might generate a blank page as a separator. • Check with the network administrator.  The printer might be feeding two or more pages at once because the paper is difficult to separate.  The sealing tape has been left in the toner cartridge.  The toner cartridge is empty or defective.  The laser scanner door does not open properly. • Remove and reseat the toner cartridge. • Check the laser scanner shutter door for proper operation.  The toner cartridge guide is damaged, improperly positioned, or missing.  There is no transfer roller voltage. • Perform the Half Self-Test Functional Check to check all other electrophotographic processes. • Replace the transfer roller if necessary.  The high-voltage connectors are mounted on the high-voltage power supply (HVPS) PCA and protrude into the toner cartridge cavity. • Check the springs for functionality. Clean if dirty; replace if defective or missing. • The HVPS PCA is defective.  The DC controller PCA is defective.  There is no developing bias. • Clean the HVPS contacts. With no developing bias charge, toner is not attracted to the drum.  There is no drum ground path. • Check the drum ground.  The laser scanner cable assembly is defective.  The page length and margins are not set correctly for the paper size. Verify that the ribbon connector at J1307 of the HVPS is properly seated.  If the HVPS has been removed recently, verify that the ribbon connector from the DC controller PCA to the HVPS is properly seated at both ends.  Verify that the photoconductive drum is rotating properly. Perform the drum diagnostic test to visually observe if the drum is rotating or using a felt-tipped marker place an index mark on the edge of the drum outside the image area. Turn on the printer (wait for drum rotation to occur), and then look to see if the drum has moved. If the drum has not moved, investigate the mechanical and electrical drum rotation circuitry and movement mechanisms.  The imaging drum shutter might not be retracting. Replace the imaging drum. 256 Troubleshooting C7085-90921

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368
  • 369
  • 370
  • 371
  • 372
  • 373
  • 374
  • 375
  • 376
  • 377
  • 378
  • 379
  • 380
  • 381
  • 382

256
Troubleshooting
C7085-90921
Blank or white pages
Your software application is sending an extra page-eject command.
Check the software’s printing configuration information.
There is a problem with the network configuration. Some sharing devices on networks might
generate a blank page as a separator.
Check with the network administrator.
The printer might be feeding two or more pages at once because the paper is difficult to
separate.
The sealing tape has been left in the toner cartridge.
The toner cartridge is empty or defective.
The laser scanner door does not open properly.
Remove and reseat the toner cartridge.
Check the laser scanner shutter door for proper operation.
The toner cartridge guide is damaged, improperly positioned, or missing.
There is no transfer roller voltage.
Perform the Half Self-Test Functional Check to check all other electrophotographic
processes.
Replace the transfer roller if necessary.
The high-voltage connectors are mounted on the high-voltage power supply (HVPS) PCA and
protrude into the toner cartridge cavity.
Check the springs for functionality. Clean if dirty; replace if defective or missing.
The HVPS PCA is defective.
The DC controller PCA is defective.
There is no developing bias.
Clean the HVPS contacts. With no developing bias charge, toner is not attracted to the
drum.
There is no drum ground path.
Check the drum ground.
The laser scanner cable assembly is defective.
The page length and margins are not set correctly for the paper size. Verify that the ribbon
connector at J1307 of the HVPS is properly seated.
If the HVPS has been removed recently, verify that the ribbon connector from the DC controller
PCA to the HVPS is properly seated at both ends.
Verify that the photoconductive drum is rotating properly. Perform the drum diagnostic test to
visually observe if the drum is rotating or using a felt-tipped marker place an index mark on the
edge of the drum outside the image area. Turn on the printer (wait for drum rotation to occur),
and then look to see if the drum has moved. If the drum has not moved, investigate the
mechanical and electrical drum rotation circuitry and movement mechanisms.
The imaging drum shutter might not be retracting. Replace the imaging drum.