HP Dl180 ProLiant DL180 Generation 5 Server Maintenance and Service Guide - Page 79
LED indicator, Status, Description - hard drive failure
UPC - 883585990917
View all HP Dl180 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Table 8 Hard drive activity LED indicator status Item 2 LED indicator Drive Online/Error LED indicator Status Description Flashing green during a • The drive is currently performing an drive activity (if I/O activity. command is outstanding • The drive is a member of a RAID continually the indicator volume. is forced to flash at 4 Hz 50% duty cycle instead of solid off) • The drive is not in a replacement or failed state for any volumes that it is a member of (drive is online). • The drive is not rebuilding. • The drive is not a member of a volume undergoing capacity expansion or RAID migration. Flashing green @ 1 Hz • 50% duty cycle (override • drive activity output) The drive is rebuilding. The drive is a member of a volume undergoing capacity expansion or RAID migration. Off • The drive is not in a failed state. • The drive is not selected (unit identification). Solid blue • The drive is not in a failed state. • The drive is selected (unit identification). Solid amber • The drive is in a failed state. • The drive is not selected. Flashing amber @ 1 Hz 50% duty cycle • The drive is in a predictive failure state. • The drive is not in a failed state. • The drive is not selected. Flashing amber/blue @ 1 • Hz 50% duty cycle • The drive is in a failed or predictive failure state. The drive is selected. Connectors, switches, and LEDs 79