HP Dl180 ProLiant DL180 Generation 5 Server Maintenance and Service Guide - Page 97

Table 12, Components, Description - dimension

Page 97 highlights

Table 12 Hardware specifications Item Status LED indicators Front panel Rear Panel System Board Power supply unit (PSU) Thermal solution Table 13 Physical dimensions Item System board platform System board dimension Server dimensions Rack Server weight Table 14 Environmental specifications Item Temperature: Operating Non-operating Storage Wet-bulb temperature Relative humidity: Operating Non-operating Storage Components • Hard Disk activity • Power/system health status • NIC 1 activity • UID status • NIC activity • LAN activity • LAN link status • Auxiliary power indicators • Processor indicator • PCI reset status 750W Redundant, power supply Four system fans Description EATX (Advanced Technology Extended) 12 in x 13 in 448W * 87.5H * 698.7D (mm) Basic configuration ( excludes keyboard and monitor): 20 kg Description +10 to +35° (+50 to +95°F) -30 to 60° (-22 to 140°F) -30 to 60° (-22 to 140°F) 38.7° (101.7°F) 10% to 90% (non-condensing) 5% to 95% 5% to 95% Physical and operating specifications 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

Physical and operating specifications
97
Table 12
Hardware specifications
Item
Components
Status LED indicators
Front panel
Rear Panel
System Board
Hard Disk activity
Power/system health status
NIC 1 activity
UID status
NIC activity
LAN activity
LAN link status
Auxiliary power indicators
Processor indicator
PCI reset status
Power supply unit (PSU)
750W Redundant, power supply
Thermal solution
Four system fans
Table 13
Physical dimensions
Item
Description
System board platform
EATX (Advanced Technology Extended)
System board dimension
12 in x 13 in
Server dimensions
Rack
448W * 87.5H * 698.7D (mm)
Server weight
Basic configuration ( excludes keyboard and monitor):
20 kg
Table 14
Environmental specifications
Item
Description
Temperature:
Operating
Non-operating
Storage
Wet-bulb temperature
+10 to +35° (+50 to +95°F)
-30 to 60° (-22 to 140°F)
-30 to 60° (-22 to 140°F)
38.7° (101.7°F)
Relative humidit
Operating
y:
Non-operating
Storage
10% to 90% (non-condensing)
5% to 95%