HP EVA P6550 HP P6300/P6500 EVA User Guide (5697-2486, September 2013) - Page 172
Automatic data recovery (rebuild), Time required for a rebuild
![]() |
View all HP EVA P6550 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 172 highlights
To minimize the likelihood of fatal system errors, take these precautions when removing failed drives: • Do not remove a degraded drive if any other drive in the array is offline (the online LED is off). In this situation, no other drive in the array can be removed without data loss. • Exceptions: ◦ When RAID1+0 is used, drives are mirrored in pairs. Several drives can be in a failed condition simultaneously (and they can all be replaced simultaneously) without data loss, as long as no two failed drives belong to the same mirrored pair. ◦ When RAID6 is used, two drives can fail simultaneously (and be replaced simultaneously) without data loss. ◦ If the offline drive is a spare, the degraded drive can be replaced. • Do not remove a second drive from an array until the first failed or missing drive has been replaced and the rebuild process is complete. (The rebuild is complete when the Online LED on the front of the drive stops blinking.) Exceptions: ◦ In RAID6 configurations, any two drives in the array can be replaced simultaneously. ◦ In RAID1+0 configurations, any drives that are not mirrored to other removed or failed drives can be simultaneously replaced offline without data loss. Automatic data recovery (rebuild) When you replace a disk drive in an array, the controller uses the fault-tolerance information on the remaining drives in the array to reconstruct the missing data (the data that was originally on the replaced drive) and write it to the replacement drive. This process is called automatic data recovery, or rebuild. If fault tolerance is compromised, this data cannot be reconstructed and is likely to be permanently lost. Time required for a rebuild The time required for a rebuild varies considerably, depending on several factors: • The priority that the rebuild is given over normal I/O operations • The amount of I/O activity during the rebuild operation • The rotational speed of the disk drives • The availability of drive cache • The model and age of the drives • The amount of unused capacity on the drives • The number of drives in the array (for RAID5 and RAID6 ) Allow approximately 5 minutes per gigabyte without any I/O activity during the rebuild process. This figure is conservative, and newer drive models usually require less time to rebuild. System performance is affected during the rebuild, and the system is unprotected against further drive failure until the rebuild has finished. Therefore, replace drives during periods of low activity when possible. CAUTION: If the Online LED of the replacement drive stops blinking and the amber fault LED glows, or if other drive LEDs in the array go out, the replacement drive has failed and is producing unrecoverable disk errors. Remove and replace the failed replacement drive. 172 Troubleshooting
![](/manual_guide/products/hewlettpackard-eva-p6550-hp-p6300p6500-eva-user-guide-56972486-2013-4330a37/172.png)