HP EVA P6550 HP P6300/P6500 EVA User Guide (5697-2486, September 2013) - Page 191

DRM Group Is Already Present, Too Many Physical Store Tags

Page 191 highlights

Table 27 Error Messages (continued) Status code value Meaning How to correct 146 Specified Option Iis Not Yet Implemented An unsupported code load attempt was made. Code load the EVA firmware with a supported method. 147 Data replication group is already DRM Group Is Already "Present present_only. Only" Disable active-active or read-only and retry operation. 148 The Presented Unit Identifier Is Invalid This error is no longer supported. Report the error to product support. 149 Internal SCS Error This is an internal error. Report the error to product support. 150 Invalid SCS Function Code This is an internal error. Report the error to product support. 151 The command is not supported. Unsupported SCS Function Code Report the error to product support. 152 Init PS Failed The requested command cannot be Replace the failed drive and retry the completed because a physical drive is failed. command. 153 Target Bad Identifier The object identifier included with the Verify that the parameters of the command is invalid. This can indicate a user command are correct and retry. or program error. 154 Physcial Store Is Volume This error is no longer supported. Report the error to product support. 155 Bad Volume Usage The requested "usage" of the volume is not Verify that the parameters of the a valid value. This can indicate a user or command are correct and retry. program error. 156 Bad LDAD Usage The requested "usage" of the volume is not Verify that the parameters of the a consistent with the disk group indicated. command are correct and retry. This can indicate a user or program error. 157 No LDAD Handle The disk group requested for the attempted Verify that the parameters of the command is not valid. command are correct and retry. 158 Bad Quorum Flag This error is no longer supported. Report the error to product support. 159 Internal Tag Invalid The command parameters do not correlate Verify that the parameters of the to an object in the system. This can indicate command are correct and retry. a user or program error. 160 Internal Tag Bad UUID The command parameters do not correlate Verify that the parameters of the to an object in the system. This can indicate command are correct and retry. a user or program error. 161 Too Many Physical Store Tags When attempting to initialize the storage cell, either the command is attempted with too many drives, or the drive list has duplicate entries. Ensure that a supported number of drives are used to initialize the storage cell, and that the drives are each included only once. 162 Bad Routine This error indicates that a product support Report the error to product support. command is invalid or no longer supported. 163 No Tag For Identifier The identifier supplied with the command does not correspond to an object in the system. Verify that the parameters of the command are correct and retry. 164 Bad Loop Number This error only applies to product support Report the error to product support. commands. 191

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316

Table 27 Error Messages
(continued)
How to correct
Meaning
Status code value
Code load the EVA firmware with a
supported method.
An unsupported code load attempt was
made.
146
Specified Option Iis Not Yet
Implemented
Disable active-active or read-only and
retry operation.
Data replication group is already
present_only.
147
DRM Group Is Already “Present
Only”
Report the error to product support.
This error is no longer supported.
148
The Presented Unit Identifier Is
Invalid
Report the error to product support.
This is an internal error.
149
Internal SCS Error
Report the error to product support.
This is an internal error.
150
Invalid SCS Function Code
Report the error to product support.
The command is not supported.
151
Unsupported SCS Function Code
Replace the failed drive and retry the
command.
The requested command cannot be
completed because a physical drive is failed.
152
Init PS Failed
Verify that the parameters of the
command are correct and retry.
The object identifier included with the
command is invalid. This can indicate a user
or program error.
153
Target Bad Identifier
Report the error to product support.
This error is no longer supported.
154
Physcial Store Is Volume
Verify that the parameters of the
command are correct and retry.
The requested "usage" of the volume is not
a valid value. This can indicate a user or
program error.
155
Bad Volume Usage
Verify that the parameters of the
command are correct and retry.
The requested "usage" of the volume is not
a consistent with the disk group indicated.
This can indicate a user or program error.
156
Bad LDAD Usage
Verify that the parameters of the
command are correct and retry.
The disk group requested for the attempted
command is not valid.
157
No LDAD Handle
Report the error to product support.
This error is no longer supported.
158
Bad Quorum Flag
Verify that the parameters of the
command are correct and retry.
The command parameters do not correlate
to an object in the system. This can indicate
a user or program error.
159
Internal Tag Invalid
Verify that the parameters of the
command are correct and retry.
The command parameters do not correlate
to an object in the system. This can indicate
a user or program error.
160
Internal Tag Bad UUID
Ensure that a supported number of
drives are used to initialize the storage
When attempting to initialize the storage
cell, either the command is attempted with
161
Too Many Physical Store Tags
cell, and that the drives are each
included only once.
too many drives, or the drive list has
duplicate entries.
Report the error to product support.
This error indicates that a product support
command is invalid or no longer supported.
162
Bad Routine
Verify that the parameters of the
command are correct and retry.
The identifier supplied with the command
does not correspond to an object in the
system.
163
No Tag For Identifier
Report the error to product support.
This error only applies to product support
commands.
164
Bad Loop Number