3. Do one of the following: • Click Downgrade or Rewrite, depending on whether you want to downgrade the firmware version, or overwrite the current firmware version. • Force upgrade bundles, firmware, or software. ◦ Bundles-Selects older firmware bundles. ◦ Firmware-Selects older firmware components. ◦ Software-Selects older software bundles. NOTE: You cannot use HP SUM to downgrade a Virtual Connect, Ethernet, or Fibre Channel module Reboot options If you set the reboot options on the Review/Install Updates screen, they are set for all the targets. If you want to set the reboot options for only specific targets, click Select Bundles or Select Components for the target, and then click Reboot Options for the target. NOTE: For Superdome 2 servers, the reboot options are set for each partition on the Select Devices screen. HP SUM does not support global reboot options for Superdome 2 servers. To set the reboot options: 1. Click Reboot Options. 2. Check Reboot System After Installation to set the reboot. 3. Check If Needed or Always. 4. Click OK. NOTE: Reboot Delay and Reboot Message do not apply for HP Integrity iLO or HP Superdomes 2 servers. Scheduling updates Use these steps to schedule a time to run the updates. 1. Click Schedule Update. 2. Click Create Schedule, type a schedule name, and then click OK. 3. Select the targets or groups from the Unscheduled Targets list, and then click Add. 4. Select a date and time to start the updates. Check UTC if you want to use Coordinated Universal Time, and not the time zone listed in the Time Zone field. 5. Click Save and Continue, click Done, and then click OK. If you click the X to close the window will not save the schedule. 6. The schedule details are updated in the Target Status. 7. The schedule is completed when you click Install on the Review/Install Updates screen. NOTE: If the Install button is grayed out, make sure you enter all required information on the Review/Install Updates screen. For more information, see "Reviewing and installing updates" (page 24). NOTE: Schedule settings might be lost if the HP SUM session is closed. HP recommends not to exit from an HP SUM session if a scheduled update has been set. Scheduling updates 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

3.
Do one of the following:
Click
Downgrade
or
Rewrite
, depending on whether you want to downgrade the firmware
version, or overwrite the current firmware version.
Force upgrade bundles, firmware, or software.
Bundles—Selects older firmware bundles.
Firmware—Selects older firmware components.
Software—Selects older software bundles.
NOTE:
You cannot use HP SUM to downgrade a Virtual Connect, Ethernet, or Fibre
Channel module
Reboot options
If you set the reboot options on the Review/Install Updates screen, they are set for all the targets.
If you want to set the reboot options for only specific targets, click
Select Bundles
or
Select
Components
for the target, and then click
Reboot Options
for the target.
NOTE:
For Superdome 2 servers, the reboot options are set for each partition on the Select
Devices screen. HP SUM does not support global reboot options for Superdome 2 servers.
To set the reboot options:
1.
Click
Reboot Options
.
2.
Check
Reboot System After Installation
to set the reboot.
3.
Check
If Needed
or
Always
.
4.
Click
OK
.
NOTE:
Reboot Delay and Reboot Message do not apply for HP Integrity iLO or HP
Superdomes 2 servers.
Scheduling updates
Use these steps to schedule a time to run the updates.
1.
Click
Schedule Update
.
2.
Click
Create Schedule
, type a schedule name, and then click
OK
.
3.
Select the targets or groups from the Unscheduled Targets list, and then click
Add
.
4.
Select a date and time to start the updates. Check
UTC
if you want to use Coordinated Universal
Time, and not the time zone listed in the Time Zone field.
5.
Click
Save and Continue
, click
Done
, and then click
OK
. If you click the
X
to close the window
will not save the schedule.
6.
The schedule details are updated in the Target Status.
7.
The schedule is completed when you click
Install
on the Review/Install Updates screen.
NOTE:
If the
Install
button is grayed out, make sure you enter all required information on
the Review/Install Updates screen. For more information, see
“Reviewing and installing
updates” (page 24)
.
NOTE:
Schedule settings might be lost if the HP SUM session is closed. HP recommends
not to exit from an HP SUM session if a scheduled update has been set.
Scheduling updates
29