HP Integrity Superdome 2 8/16 HP Smart Update Manager 5.3 User Guide - Page 38

Connect Ethernet or Fibre Channel Module for c-Class, Description, Targets, Log files

Page 38 highlights

Targets /targettype /current_credential /oa_username /_password Log files /logdir "path" 38 Using scripts to deploy updates Description Connect Ethernet or Fibre Channel Module for c-Class BladeSystem, or BladeSystem OA. When two OAs are in an enclosure, this argument should be the active OA. When specifying the IP address, use either the IPv4 or IPv6 format. Discovery will be triggered for the specified target type, only. This option can reduce discovery time for scripted deployments. This is an optional command line argument. Use /targettype with /target parameter. You can interchange the sequence of /targettype and /target. If the target name includes spaces, make sure you enclose the name in quotation marks, " ". Enables the credential of the local host to be used as the credential to access the targets instead of providing the user name and password explicitly for each target. The assumption is that the current credential is valid for the targets being accessed. (Applies to Windows only) This argument provides the user name credential for OA associated with VC specified with the target command-line parameter. Only one set of OA credentials can be specified with command-line parameters. You can add multiple VC targets to command-line parameters with the target parameter only if the credentials of OAs associated with specified VCs are the same. The argument oa_username is not required if VC has the same credentials as the associated OA. You do not need to provide an OA network address associated with VC. HP SUM queries it from a specified VC target. To update multiple VCs with different user names and passwords, or VCs with OAs that have different credentials, use the corresponding input files OAUID and OAPWD. Provides the password credential for OA associated with VC specified with the "target" command-line parameter. Only one set of OA credentials can be specified with command-line parameters. You can add multiple VC targets to command-line parameters with the "target" parameter only if the credentials of OAs associated with specified VCs are the same. The argument oa_password is not required if VC has the same credentials as the associated OA. You do not need to provide an OA network address associated with VC. HP SUM queries it from a specified VC target. To update multiple VCs with different user names and passwords, or VCs with OAs that have different credentials, use the corresponding input files OAUID and OAPWD . Description Redirects the output from HP SUM or the HP BladeSystem c-Class OA flash utility to a different directory than the default location. • For Windows components, the default location is %SYSTEMDRIVE%\CPQSYSTEM\hp\

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

Description
Targets
Connect Ethernet or Fibre Channel Module for c-Class
BladeSystem, or BladeSystem OA.
When two OAs are in an enclosure, this argument should
be the active OA. When specifying the IP address, use
either the IPv4 or IPv6 format.
Discovery will be triggered for the specified target type,
only. This option can reduce discovery time for scripted
deployments. This is an optional command line argument.
/targettype
Use
/targettype
with
/target
parameter. You can
interchange the sequence of
/targettype
and
/target
.
If the target name includes spaces, make sure you enclose
the name in quotation marks,
.
Enables the credential of the local host to be used as the
credential to access the targets instead of providing the
/current_credential
user name and password explicitly for each target. The
assumption is that the current credential is valid for the
targets being accessed. (Applies to Windows only)
This argument provides the user name credential for OA
associated with VC specified with the
target
/oa_username
command-line parameter. Only one set of OA credentials
can be specified with command-line parameters. You can
add multiple VC targets to command-line parameters with
the
target
parameter only if the credentials of OAs
associated with specified VCs are the same. The argument
oa_username
is not required if VC has the same
credentials as the associated OA. You do not need to
provide an OA network address associated with VC. HP
SUM queries it from a specified VC target.
To update multiple VCs with different user names and
passwords, or VCs with OAs that have different credentials,
use the corresponding input files
OAUID
and
OAPWD
.
Provides the password credential for OA associated with
VC specified with the "target" command-line parameter.
/_password
Only one set of OA credentials can be specified with
command-line parameters. You can add multiple VC targets
to command-line parameters with the "target" parameter
only if the credentials of OAs associated with specified
VCs are the same. The argument
oa_password
is not
required if VC has the same credentials as the associated
OA. You do not need to provide an OA network address
associated with VC. HP SUM queries it from a specified
VC target.
To update multiple VCs with different user names and
passwords, or VCs with OAs that have different credentials,
use the corresponding input files
OAUID
and
OAPWD
.
Description
Log files
Redirects the output from HP SUM or the HP BladeSystem
c-Class OA flash utility to a different directory than the
default location.
/logdir
“path"
For Windows components, the default location is
%SYSTEMDRIVE%\CPQSYSTEM\hp\
38
Using scripts to deploy updates